Dynamic Calibration Method for Instrumented Laparoscopic Surgical Graspers1
Bibliographic record
Abstract
The prevalence of minimally invasive surgical (MIS) procedures is on the rise due to the promise of fewer complications; however, these surgeries are more technically difficult and require greater training than their traditional counterparts. To counteract this, surgeons undergo more training and utilize surgical simulators to gain experience without risking patients' health. To increase the accuracy and, therefore, effectiveness of the surgical simulators, tissue property databases have been created, such as the Human Tissue Property Database created by the Center for Research in Education and Simulation Technologies, which test excised tissues postmortem for their mechanical properties [1]. Databases such as this have potential beyond their utilization in simulation and may serve as a platform for automated diagnostic systems capable of characterizing the health of tissues during surgical procedures [2]. Because of the importance to surgical simulation now and in the future of automated diagnostics, tissue property databases must better their accuracy to reflect the complex mechanical behavior of biological samples in vivo [2,3]. This upgrade requires the development of instrumentation capable of collecting data nondestructively in vivo, as well as nonintrusively to a surgical environment.A promising approach to collecting data nondestructively and nonintrusively during surgical procedures is the modification of current MIS tools to contain sensors, and occasionally actuators separate from the operating area [3–6]. Due to the small size of the operating component and the slender connection to the handle, it is not practical to include these additions to the tool anywhere except the handle. Tools, such as the motorized smart endoscopic grasper (MSEG) tool, created by the BioRobotics Lab at the University of Washington, utilize a strain gauge and encoder equipped motor in place of the handle to provide actuation to the jaw and record the stress and strain experienced by the tissue being grasped [6]. Previous efforts to calibrate the MSEG system by the Medical Robotics and Devices Lab at the University of Minnesota have focused on static loading at discrete locations rather than quasi-static loading recorded continuously over a range of the tool's motion [7]. This paper describes the latter method of calibration in order to provide more accurate interpretation of the friction and momentum within the system.With a calibrated instrument capable of recording data in vivo as well as for benchtop testing, it is possible to create a model of tissue property decay with respect to time postmortem. Successfully doing this with a standardized excision and storage procedure can allow accurate in vivo properties to be derived from the abundance of previously collected ex vivo data currently in databases. This ability to back-compute more meaningful information from already available sources promises to have significant impacts on healthcare through higher quality surgical simulations as well as by providing a reference platform for diagnostic equipment to evolve from. Beyond healthcare, the successful modeling of tissue degradation can impact the field of biomechanics by allowing the compilation and utilization of collected data between studies encouraging greater collaboration to occur.To calibrate the instruments, a method was necessary to record dynamic distal grasping force and jaw position and compare it with the recorded force and handle position. To accomplish this, a benchtop platform was created to record data while analysis was done using matlab (MathWorks, Natick, MA). The instrument used in this testing was the instrumented Babcock grasper as used by Sie [7].The distal sensor platform seen in Fig. 1 consisted of a digital caliper (Neiko Tools, China) with a shear load cell rated to 780 g (Phidgets, Calgary, Alberta) attached to each outside jaw via aluminum mounts. Attached to each load cell is an aluminum extension defining the location surgical graspers can squeeze.This system connects to a circuit built around an AD623 Instrumentation Amplifier (Analog Devices, Inc, Norwood, MA) that is connected to a host computer through an Arduino Uno (Smart Projects, Italy) that time stamps the samples and sends them to a serial com capture utility via a USB 2.0 connection.The sensor platform was calibrated with dead weights to a linear fit (Fig. 2).Repeated trapezoidal loading was applied to the instrument, while load and position information were recorded for both the jaw and handle portion of the tool. Multiple separations were set in the calibration caliper to create an effective map of the force mapping. Data sets were time-aligned by finding the scale and offset constants TS and T0 to minimize total error = ∑t|ForceHandle,i-ForceJaw,i|. Figure 3 shows the accuracy of the predicted jaw displacement and force to the measured jaw displacement and force, respectively. Figure 4 shows the FJaw and dJaw response to FHandle and θHandle.The instrumented Babcock grasper was taken to the visible heart lab (VHL) at the University of Minnesota where in vivo compressions could be recorded. The same tissues were then excised and tested at frequent intervals using the same Babcock grasper. Collected data are seen in Fig. 5.Representative preliminary data in Fig. 5 show that there is substantial change in the tissue properties following sacrifice of the animal and excision. We see the in vivo data collection experienced greater resistance to compression. This is shown by larger forces experienced than ex vivo samples for given compressions. Additionally, there is a trend in diminishing mechanical response in the liver present in these recordings. This behavior was representative of changes recorded for multiple tissue types excised from sacrificed porcine specimens made available by collaborators at the VHL. The causes of tissue property decay are widespread, including changes in temperature, environment, and fluid loss [2]. To minimize these changes, common practices include utilization of stabilizing solutions to retard decay and controlling environmental factors to match in vivo conditions as closely as possible; however, time is not a factor that can be controlled so researchers must rush to test samples as soon as possible after sacrifice while attempting to maintain consistent times for each specimen, a task that can be difficult if not impossible due to logistical problems and unforeseen technical obstacles faced when performing experiments on biological samples.The success of the instrumented Babcock grasper in collecting the decay of mechanical properties in porcine tissues is promising; however, further work must be done to develop a robust model capable of accurately predicting change.Future work will address the remaining inaccuracy in the dynamic calibration of the instrumented Babcock grasper as seen in Figs. 2 and 3 to extract more accurate data for tissue property decay model development.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".