MétaCan
Menu
Back to cohort
Record W2066543915 · doi:10.1021/ac000629k

Design and Validation of Portable SPME Devices for Rapid Field Air Sampling and Diffusion-Based Calibration

2000· article· en· W2066543915 on OpenAlexafffund
Fábio Augusto, Jacek A. Koziel, Janusz Pawliszyn

Bibliographic record

VenueAnalytical Chemistry · 2000
Typearticle
Languageen
FieldEngineering
TopicAdvanced Chemical Sensor Technologies
Canadian institutionsUniversity of Waterloo
FundersNational Institute for Occupational Safety and HealthNatural Sciences and Engineering Research Council of CanadaFundação de Amparo à Pesquisa do Estado de São Paulo
KeywordsChemistryCalibrationSampling (signal processing)Solid-phase microextractionExtraction (chemistry)FiberDiffusionChromatographyVolatile organic compoundCalibration curveContaminationAdsorptionAnalytical Chemistry (journal)Environmental chemistryDetection limitMass spectrometryGas chromatography–mass spectrometry

Abstract

fetched live from OpenAlex

The use of SPME fibers coated with porous polymer solid phases for quantitative purposes is limited due to effects such as interanalyte displacement and competitive adsorption. For air analysis, these problems can be averted by employing short exposure times to air samples flowing around the fiber. In these conditions, a simple mathematical model allows quantification without the need of calibration curves. This work describes two portable dynamic air sampling (PDAS) devices designed for application of this approach to nonequilibrium SPME sampling and determination of airborne volatile organic compounds (VOCs). The use of a PDAS device resulted in greater adsorbed VOC mass compared to the conventional SPME extraction in static air for qualitative screening of live plant aromas and contaminants in indoor air. For all studied air samples, an increase in the number of detected compounds and sensitivity was also observed. Quantification of aromatic VOCs in indoor air was also carried out using this approach and the PDAS/SPME device. Measured VOC concentrations were in low parts-per-billion by volume range using only 30-s SPME fiber exposure and were comparable to those obtained with a standard NIOSH method 1501. The use of PDAS/SPME devices reduced the total air sampling and analysis time by several orders of magnitude compared to the NIOSH 1501 method.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.004
Threshold uncertainty score0.022

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.005
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0020.001
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.239
Teacher spread0.223 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations130
Published2000
Admission routes2
Has abstractyes

Explore more

Same venueAnalytical ChemistrySame topicAdvanced Chemical Sensor TechnologiesFrench-language works237,207