Bibliographic record
Abstract
Ferrous ions and xylenol orange dissolved in sulfuric acid (FX) is a common radiochromic chemical dosimeter for water‐equivalent dosimetry. The versatility of this reaction is extended by using it to readout dose deposited in materials that are soluble in FX. Sucrose has been used as a tissue‐equivalent dosimeter with electron spin resonance readout. In this work, doses recorded in sucrose are measured by dissolving the sugar into FX and recording the change in transmission at 590 nm. Conventional transmission measurements with a UV‐VIS absorption spectrometer and 10 cm cuvettes, determined a dose response of approximately 0.02 cm −1 Gy −1 with 10% sucrose‐FX solutions. Fructose, propylene glycol and water had lower but measurable dose sensitivities. Long liquid waveguides were investigated as a means to increase the transmission measurement sensitivity. Hydrophobic Teflon® FEP tubing and hydrophilic thin‐walled glass capillary tubing were both investigated. The Teflon® tubing was unsuitable to due large changes in transmission with time. This phenomenon was attributed to a lack of surface wetting by the aqueous solutions. The glass capillary waveguide provided stable transmission measurements. A linear response was measured with 0.4 g sucrose samples from 0.5 to 3 Gy with a 60 cm long glass tube. Optimizing the measurement conditions will allow measurement of 0.1 g sucrose samples to a minimum dose of approximately 0.1 Gy. Sucrose with optical readout is a simple and inexpensive dosimetry system.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".