MétaCan
Menu
Back to cohort
Record W2068237805 · doi:10.1002/jmri.22230

Feasibility and precision of cerebral blood flow and cerebrovascular reactivity MRI measurements using a computer‐controlled gas delivery system in an anesthetised juvenile animal model

2010· article· en· W2068237805 on OpenAlexaff
Jeff D. Winter, Jorn Fierstra, Stephanie Dorner, Joseph A. Fisher, Keith St. Lawrence, Andrea Kassner

Bibliographic record

VenueJournal of Magnetic Resonance Imaging · 2010
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsWestern UniversityLawson Health Research InstituteUniversity of TorontoUniversity Health NetworkHospital for Sick Children
Fundersnot available
KeywordsRepeatabilityCerebral blood flowMedicineBlood flowCoefficient of variationNuclear medicineMagnetic resonance imagingBreathingVentilation (architecture)Repeated measures designAnesthesiaBiomedical engineeringCardiologyRadiologyChemistryMathematics

Abstract

fetched live from OpenAlex

PURPOSE: To demonstrate the feasibility and repeatability of cerebrovascular reactivity (CVR) imaging using a controlled CO(2) challenge in mechanically ventilated juvenile pigs. MATERIALS AND METHODS: Precise end-tidal partial pressure CO(2) (PETCO(2)) control was achieved via a computer-controlled model-driven prospective end-tidal targeting (MPET) system integrated with mechanical ventilation using a custom-built secondary breathing circuit. Test-retest blood-oxygen level dependent (BOLD) CVR images were collected in nine juvenile pigs by quantifying the BOLD response to iso-oxic square-wave PETCO(2) changes. For comparison, test-retest baseline arterial spin labeling (ASL) cerebral blood flow (CBF) images were collected. Repeatability was quantified using the intra-class correlation coefficient (ICC) and coefficient of variation (CV). RESULTS: The repeatability of the PETCO(2) (CV < 2%) step changes resulted in BOLD CVR ICC > 0.94 and CV < 6% for cortical brain regions, which was similar to ASL CBF repeatability (ICC > 0.96 and CV < 4%). CONCLUSION: This study demonstrates the feasibility and precision of CVR imaging with an MPET CO(2) challenge in mechanically ventilated subjects using an animal model. Translation of this method into clinical imaging protocols may enable CVR imaging in young children with cerebrovascular disease who require general anesthesia.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.009

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.026
GPT teacher head0.289
Teacher spread0.262 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations13
Published2010
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Magnetic Resonance ImagingSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207