MétaCan
Menu
Back to cohort
Record W2068804147 · doi:10.1080/15459624.2014.955179

Creatinine and Specific Gravity Normalization in Biological Monitoring of Occupational Exposures

2014· article· en· W2068804147 on OpenAlexaffabout
Jean‐François Sauvé, Martine Lévesque, Mélanie Huard, D. Drolet, Jérôme Lavoué, Robert Tardif, Ginette Truchon

Bibliographic record

VenueJournal of Occupational and Environmental Hygiene · 2014
Typearticle
Languageen
FieldMedicine
TopicBody Composition Measurement Techniques
Canadian institutionsInstitut de Recherche Robert-Sauvé en Santé et en Sécurité du TravailUniversité de Montréal
Fundersnot available
KeywordsCreatinineUrineMedicineUrine specific gravityThreshold limit valueOccupational exposureUrinary systemLinear relationshipReference valuesUrologyToxicologyChemistryStatisticsEnvironmental healthInternal medicineMathematicsBiology

Abstract

fetched live from OpenAlex

Reference values for the biological monitoring of occupational exposures are generally normalized on the basis of creatinine (CR) concentration or specific gravity (SG) to account for fluctuations in urine dilution. For instance, the American Conference of Governmental Industrial Hygienists (ACGIH(®)) uses a reference value of 1g/L for CR. The comparison of urinary concentrations of biomarkers between studies requires the adjustment of results based on a reference CR and/or SG value, although studies have suggested that age, sex, muscle mass, and time of the day can exert non-negligible influences on CR excretion, while SG appears to be less affected. The objective of this study was to propose reference values for urinary CR and SG based on the results of samples sent for analysis by occupational health practitioners to the laboratory of the Occupational Health and Safety Research Institute of Québec (IRSST). We analyzed a database containing 20,395 urinary sample results collected between 1985 and 2010. Linear mixed-effects models with worker as a random effect were used to estimate the influence of sex and collection period on urinary CR and SG. Median CR concentrations were 25-30% higher in men (1.6 g/L or 14.4 mmol/L) than in women (1.2 g/L or 10.2 mmol/L). Four percent of the samples for men and 12% for women were below the acceptable threshold for CR (4.4 mmol/L). For SG, 5% of samples for men and 12% for women were below the threshold of 1.010. The difference in SG levels between sexes was lower than for CR, with a median of 1.024 for men compared to 1.020 for women. Our results suggest that the normalization of reference values based on a standard CR value of 1 g/L as proposed by the ACGIH is a conservative approach. According to the literature, CR excretion is more influenced by physiological parameters than SG. We therefore suggest that correction based on SG should be favored in future studies involving the proposal of reference values for the biological monitoring of occupational exposures.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.025
metaresearch head score (Gemma)0.032
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Theoretical or conceptual · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.030
Threshold uncertainty score0.134

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0250.032
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0020.002
Bibliometrics0.0060.009
Science and technology studies0.0010.002
Scholarly communication0.0020.001
Open science0.0030.001
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.050
GPT teacher head0.296
Teacher spread0.246 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designTheoretical or conceptual
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations116
Published2014
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Occupational and Environmental HygieneSame topicBody Composition Measurement TechniquesFrench-language works237,207