MétaCan
Menu
Back to cohort
Record W2069239365 · doi:10.1118/1.3665706

Aperture superposition dose model versus pencil beam superposition dose model for a finite size Cobalt-60 source for tomotherapy deliveries

2011· article· en· W2069239365 on OpenAlexafffund
S Dhanesar, Johnson Darko, L J Schreiner

Bibliographic record

VenueMedical Physics · 2011
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsQueen's University
FundersCanadian Institutes of Health ResearchViewRay
KeywordsTomotherapySuperposition principleSource modelDosimetryPencil (optics)PhysicsCobalt-60OpticsBeam (structure)Nuclear medicineMedicineComputational physicsRadiation therapyRadiologyNuclear physicsIrradiation

Abstract

fetched live from OpenAlex

PURPOSE: The finite size pencil beam (FSPB) superposition method is a commonly used dose calculation method in intensity modulated radiation therapy (IMRT). The FSPB model assumes that dose for a broad intensity modulated beam can be calculated by superposition of dose from small, pencil-like beams. However, this model is limited to point-like radiation sources and is not valid for finite size sources, such as a Cobalt-60 (Co-60) source of 2 cm diameter. In this paper, the authors present results that show the limitation of this model and propose an alternative model, namely the aperture superposition (AS) model, to calculate photon dose for intensity modulated beams arising from finite size radiation sources. METHODS: The AS model is based on adding beam apertures rather than pencil beams. Each aperture is defined as a series of adjacently opened leaves of a multileaf collimator with no closed leaves in between them. The apertures are calculated using the EGSnrc Monte Carlo program. The accuracy of the AS model was tested for dose calculations of fan beams, as encountered in tomotherapy treatment plans. The results were compared with the FSPB model and GafChromic film measurements. The measurements and simulations were performed for a clinical Theratronics T780C Co-60 unit with MIMiC binary multileaf collimator mounted on it. RESULTS: The comparisons between the AS model and film measurements show agreement better than 1.5% in the high dose regions and 3.7% in the low dose regions. On the contrary, film measurement comparisons to the FSPB model show that the FSPB model underestimates the dose by up to 7% for small field sizes such as 2 × 2 cm(2) and 20% for larger field sizes such as 20 × 2 cm(2). CONCLUSIONS: The results presented in this paper indicate that the AS model provides better accuracy than the FSPB model when calculating dose for fan beams from large radiation sources. The implementation of this model to the current treatment planning systems has the scope of advancing Co-60 based IMRT and tomotherapy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.006
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.035
GPT teacher head0.285
Teacher spread0.251 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2011
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207