MétaCan
Menu
Back to cohort

Selection of a Polyurethane Membrane for the Manufacture of Ventricles for a Totally Implantable Artificial Heart: Blood Compatibility and Biocompatibility Studies

2000· article· en· W2069438393 on OpenAlexaff
Marie–Claire Bélanger, Yves Marois, Raynald Roy, Yahye Mehri, Éric Wagner, Ze Zhang, Martin W. King, Mingjing Yang, Charles W. Hahn, Robert Guidoin

Bibliographic record

VenueArtificial Organs · 2000
Typearticle
Languageen
FieldMaterials Science
TopicElectrospun Nanofibers in Biomedical Applications
Canadian institutionsMontreal Heart InstituteUniversité LavalHôpital Saint-François d'Assise
Fundersnot available
KeywordsBiocompatibilityHemolysisViability assayMembraneChemistryEx vivoCell adhesionFibrinIn vitroNuclear chemistryMaterials scienceCellImmunologyBiochemistryMedicineOrganic chemistry

Abstract

fetched live from OpenAlex

Membranes made from 4 commercial poly(carbonate urethanes): Carbothane (CB), Chronoflex (CF), Corethane 80A (CT80), and Corethane 55D (CT55), and from 2 poly(ether urethanes): Tecoflex (TF) and Tecothane (TT) were prepared by solution casting and sterilized by either ethylene oxide (EO) or gamma radiation. Their biocompatibility was evaluated in vitro in terms of proliferation, cell viability, and adhesion characteristics of human umbilical veins (HUVEC), monocytes (THP-1), and skin fibroblasts, and by measuring complement activation through the generation of the C3a complex. Their hemocompatibility was determined by measuring the level of radiolabeled platelet, neutrophil, and fibrin adhesion in an ex vivo arteriovenous circuit study in piglets as well as via an in vitro hemolysis test. The results of this study showed no endothelial cell proliferation on any of the materials. The cell viability study revealed that the CB, CF, and TF membranes sterilized by EO maintained the highest percentage of monocyte viability after 72 h of incubation (>70%) while none of the gamma-sterilized membranes displayed any cell viability. The fibroblast adhesion and C3a generation assays revealed that none of the materials supported any cell adhesion or activated complement, regardless of the sterilization method. The hemolysis test also confirmed that the 4 poly(carbonate urethanes) were hemolytic while none of the poly(ether urethanes) were. Finally, the ex vivo study revealed that significantly more platelets adhered to the CB and CT55 membranes while the levels of neutrophil and fibrin deposition were observed to be similar for all 6 materials. In conclusion, the study identified the CF and TF membranes as having superior biocompatibility and hemocompatibility compared to the other polyurethanes.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.002

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.027
GPT teacher head0.303
Teacher spread0.276 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations63
Published2000
Admission routes1
Has abstractyes

Explore more

Same venueArtificial OrgansSame topicElectrospun Nanofibers in Biomedical ApplicationsFrench-language works237,207