MétaCan
Menu
Back to cohort
Record W2070207499 · doi:10.1186/ar2548

Limited reliability of the indirect immunofluorescence technique for the detection of anti-Rib-P antibodies

2008· article· en· W2070207499 on OpenAlexafffund
Michael Mähler, Jennifer Ngo, Johannes Schulte-Pelkum, Tanja Luettich, Marvin J. Fritzler

Bibliographic record

VenueArthritis Research & Therapy · 2008
Typearticle
Languageen
FieldMedicine
TopicSystemic Lupus Erythematosus Research
Canadian institutionsUniversity of Calgary
FundersCanadian Institutes of Health ResearchArthritis SocietyUniversity of Calgary
KeywordsRheumatologyImmunofluorescenceMedicineIndirect immunofluorescenceAntibodyReliability (semiconductor)Internal medicineImmunology

Abstract

fetched live from OpenAlex

INTRODUCTION: Autoantibodies to the ribosomal P proteins represent a highly specific marker for the diagnosis of systemic lupus erythematosus, where they have been associated with certain clinical manifestations. Historically, autoantibodies against ribosomal P proteins have been detected by indirect immunofluorescence, immunodiffusion, immunoblot, and other immunoassays. More recently, enzyme-linked immunosorbent assays and line and addressable laser bead immunoassays have become more widely used. The primary goal of this study was to determine the sensitivity of indirect immunofluorescence using conventional HEp-2 substrates in the detection of sera with ribosomal P antibodies as detected by other immunoassays. METHODS: Anti-ribosomal P-positive sera (n = 345) as detected by an addressable laser bead immunoassay were collected between 2003 and 2007 and analysed by indirect immunofluorescence. Furthermore, 51 anti-ribosomal P-positive samples from an unselected systemic lupus erythematosus cohort (n = 100) and the Centers for Disease Control and Prevention (CDC) anti-nuclear antibody (ANA) reference sera were tested for anti-ribosomal P reactivity. RESULTS: In the cohort of 345 anti-ribosomal P-positive samples identified by addressable laser bead immunoassay, a low sensitivity (<30%) of indirect immunofluorescence on HEp-2 cell substrates was observed. Although the degree of sensitivity varied among different manufacturers, all immunofluorescence substrates exhibited limited sensitivity and false-negative results were not restricted to samples with low anti-ribosomal P titers. Even the anti-ribosomal P reactivity of CDC ANA reference serum number 12 was not clearly predictable by indirect immunofluorescence. Comparison of five different methods for the detection of anti-ribosomal P found moderate qualitative agreements. CONCLUSIONS: Based on our data, we conclude that indirect immunofluorescence on HEp-2 cells is not a reliable screening test for the prediction of ribosomal P antibodies. As this method is widely used as a first-line screening test for anti-nuclear and other autoantibodies, special considerations for the detection of ribosomal P antibodies are needed. As with many other autoantibodies, further effort is required for the standardisation of ribosomal P immunoassays.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.003
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.050
Threshold uncertainty score0.721

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0040.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0010.002
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.061
GPT teacher head0.350
Teacher spread0.289 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations86
Published2008
Admission routes2
Has abstractyes

Explore more

Same venueArthritis Research & TherapySame topicSystemic Lupus Erythematosus ResearchFrench-language works237,207