MétaCan
Menu
Back to cohort
Record W2070231051 · doi:10.1115/1.4023382

Variability of Computational Fluid Dynamics Solutions for Pressure and Flow in a Giant Aneurysm: The ASME 2012 Summer Bioengineering Conference CFD Challenge

2013· article· en· W2070231051 on OpenAlexafffund
David A. Steinman, Yiemeng Hoi, Paul Fahy, Liam Morris, Michael T. Walsh, Nicolas Aristokleous, Αndreas Αnayiotos, Yannis Papaharilaou, Amirhossein Arzani, Shawn C. Shadden, Philipp Berg, Gábor Janiga, Joris Bols, Patrick Segers, Neil W. Bressloff, Merih Cibiş, Frank H. Gijsen, Salvatore Cito, Jordi Pallarès, Leonard Browne, J. A. Costelloe, Adrian Gerard Lynch, Joris Degroote, Jan Vierendeels, Wenyu Fu, Aike Qiao, Simona Hodis, David F. Kallmes, Hardeep S. Kalsi, Quan Long, Vitaly O. Kheyfets, Ender A. Finol, Kenichi Kono, Adel M. Malek, Alexandra Lauric, Prahlad G. Menon, Kerem Pekkan, Mahdi Esmaily, Alison L. Marsden, M. Oshima, Kengo Katagiri, Véronique Peiffer, Yumnah Mohamied, Spencer J. Sherwin, J. Schaller, Leonid Goubergrits, Gabriel Usera, Mariana Mendina, Kristian Valen‐Sendstad, Damiaan F. Habets, Jianping Xiang, Hui Meng, Yue Yu, George Em Karniadakis, Nicholas Shaffer, Francis Loth

Bibliographic record

VenueJournal of Biomechanical Engineering · 2013
Typearticle
Languageen
FieldMedicine
TopicAortic aneurysm repair treatments
Canadian institutionsUniversity of Toronto
FundersCanadian Institutes of Health Research
KeywordsComputational fluid dynamicsMechanicsFlow (mathematics)DiscretizationVolumetric flow rateFluid dynamicsAneurysmConsistency (knowledge bases)Materials scienceLumen (anatomy)MathematicsGeologyGeometryPhysicsMedicineSurgeryMathematical analysis

Abstract

fetched live from OpenAlex

Stimulated by a recent controversy regarding pressure drops predicted in a giant aneurysm with a proximal stenosis, the present study sought to assess variability in the prediction of pressures and flow by a wide variety of research groups. In phase I, lumen geometry, flow rates, and fluid properties were specified, leaving each research group to choose their solver, discretization, and solution strategies. Variability was assessed by having each group interpolate their results onto a standardized mesh and centerline. For phase II, a physical model of the geometry was constructed, from which pressure and flow rates were measured. Groups repeated their simulations using a geometry reconstructed from a micro-computed tomography (CT) scan of the physical model with the measured flow rates and fluid properties. Phase I results from 25 groups demonstrated remarkable consistency in the pressure patterns, with the majority predicting peak systolic pressure drops within 8% of each other. Aneurysm sac flow patterns were more variable with only a few groups reporting peak systolic flow instabilities owing to their use of high temporal resolutions. Variability for phase II was comparable, and the median predicted pressure drops were within a few millimeters of mercury of the measured values but only after accounting for submillimeter errors in the reconstruction of the life-sized flow model from micro-CT. In summary, pressure can be predicted with consistency by CFD across a wide range of solvers and solution strategies, but this may not hold true for specific flow patterns or derived quantities. Future challenges are needed and should focus on hemodynamic quantities thought to be of clinical interest.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.010
metaresearch head score (Gemma)0.032
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.010
Threshold uncertainty score0.053

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0100.032
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0010.001
Scholarly communication0.0020.001
Open science0.0010.001
Research integrity0.0010.002
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.250
Teacher spread0.228 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations137
Published2013
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Biomechanical EngineeringSame topicAortic aneurysm repair treatmentsFrench-language works237,207