An axial molecular-beam diode laser spectrometer

2003· article· en· W2070419670 on OpenAlexafffund
Hans D. Osthoff, Wolfgang Jäger, Johnathon R. Walls, W. A. van Wijngaarden

Bibliographic record

VenueReview of Scientific Instruments · 2003
Typearticle
Languageen
FieldChemistry
TopicSpectroscopy and Laser Applications
Canadian institutionsYork UniversityUniversity of Alberta
FundersNetworks of Centres of Excellence of CanadaNatural Sciences and Engineering Research Council of Canada
KeywordsMolecular beamSpectrometerMaterials scienceOpticsLaserMicrowaveTunable diode laser absorption spectroscopyTunable laserPhysicsMolecule

Abstract

fetched live from OpenAlex

A mid-infrared tunable diode laser molecular-beam spectrometer for the purpose of trace gas sensing and the study of van der Waals complexes is described. The spectrometer employs a Herriott multipass cell with up to 72 passes. The sample gas is injected parallel to the optical axis through a hole at the center of the far mirror. The molecular absorption is Doppler split, resulting from the laser beam propagating parallel and antiparallel to the molecular-beam expansion. The axial expansion leads to narrower line widths and increased sensitivity, compared to the traditional vertical injection method, as a result of selective sampling of the central part of the molecular expansion with reduced Doppler broadening and longer residence time of the molecular sample in the laser beam. The molecular expansion leads also to selective signal enhancement of low-J transitions, as demonstrated for the ν3 antisymmetric stretch vibration of CO2. A microwave horn antenna was implemented into the spectrometer to enable microwave–infrared double-resonance experiments. The spectrometer performance was evaluated by recording spectra of the CO2–Ar, (CO2)2, CO2–He, and CO2–SO2 van der Waals complexes near the R(0) transition of the ν3 band of CO2 around 2349 cm−1. The feasibility of using a pulsed molecular expansion for trace gas sensing is explored.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.056
Threshold uncertainty score0.995

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0060.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.281
Teacher spread0.270 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2003
Admission routes2
Has abstractyes

Explore more

Same venueReview of Scientific InstrumentsSame topicSpectroscopy and Laser ApplicationsFrench-language works237,207