MétaCan
Menu
Back to cohort
Record W2072819311 · doi:10.1118/1.2962868

TH‐C‐332‐03: Noise Power Properties of a Cone‐Beam CT System for Breast Cancer Detection

2008· article· en· W2072819311 on OpenAlexaff
Kai Yang, Alexander L. C. Kwan, Shih-Cheng Huang, John M. Boone

Bibliographic record

VenueMedical Physics · 2008
Typearticle
Languageen
FieldMedicine
TopicDigital Radiography and Breast Imaging
Canadian institutionsUniversity of Alberta
Fundersnot available
KeywordsNoise (video)Cone beam computed tomographyOpticsNoise powerImage noisePhysicsQuantum noiseInterpolation (computer graphics)Iterative reconstructionMathematicsPower (physics)Computed tomographyMedicineImage (mathematics)Computer visionComputer science

Abstract

fetched live from OpenAlex

Purpose: To investigate the noise power properties of a cone‐beam breast CT (bCT) system. Method and Materials: Polyethylene cylinders were scanned under different acquisition conditions. Normalized noise power spectra (NNPS) were calculated from difference images by subtracting two identical scans. Multi‐dimensional NNPS were used to evaluate the noise properties of the bCT under different acquisition and reconstruction parameters including kVp, mA, number of projections, cone angle, object size, interpolation method, reconstruction filter, field of view (FOV), matrix size, and slice thickness. Results: Findings from the analysis: The bCT NNPS is rotational symmetric within the coronal plane and its shape is determined by the interpolation method and filter. For a cone angle range from 0° to 14°, the shape of the NPS curve changes slightly. The image variance increases slightly with increasing cone angle. Noise aliasing can be avoided if the sampling frequency of CT image is beyond a specific threshold. The coronal plane noise power decreases with increasing slice thickness. If the radiation dose (mA) is below a specific threshold, the electronic noise from the detector plays a dominate role and the system is no longer quantum limited. The threshold value decreases with increasing object size. When the radiation dose is beyond this threshold, the system is quantum limited. The image variance has a power law relationship of approximately −1.1 with the total dose. If the dose is increased by linearly increasing the number of projections but not the tube current, the noise power has an inverse linear relationship with the dose. When the dose level is kept constant, the image noise also depends on the x‐ray spectrum and the object size. Conclusion: A thorough investigation of the noise power was performed. Quantitative results provide guidance for the bCT system operation, optimization and data reconstruction.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.823
Threshold uncertainty score0.430

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.237
Teacher spread0.221 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicDigital Radiography and Breast ImagingFrench-language works237,207