MétaCan
Menu
Back to cohort

Monorail snare technique for the retrieval of an adherent microcatheter from an onyx cast: technical case report.

2008· article· en· W2073980778 on OpenAlexaff
Michael Kelly, Raymond D Turner, Vivek Gonugunta, Peter A. Rasmussen, Henry H. Woo, David Fiorella

Bibliographic record

VenuePubMed · 2008
Typearticle
Languageen
FieldMedicine
TopicIntracranial Aneurysms: Treatment and Complications
Canadian institutionsUniversity of SaskatchewanRoyal University Hospital
Fundersnot available
KeywordsMedicineMonorailNeurovascular bundleEmbolizationOccipital nerve stimulationOccipital arterySurgeryAnastomosis

Abstract

fetched live from OpenAlex

OBJECTIVE: Microcatheters retained after Onyx (eV3 Neurovascular, Inc., Irvine, CA) embolization represent a potential source of thromboembolic complications. Catheter retention depends on the degree of Onyx reflux and vessel tortuosity. To overcome this problem, we have adapted a previously described monorail snare technique for stretched coils to remove an adherent microcatheter from the occipital artery during Onyx embolization of a dural arteriovenous fistula. CLINICAL PRESENTATION: We used this technique successfully in a 62-year-old man with a posterior fossa dural arteriovenous fistula. An Echelon-10 microcatheter (eV3 Neurovascular, Inc.) system became adherent in the right occipital artery because of reflux and vessel tortuosity. Significant stretching of the microcatheter was observed during attempted removal. INTERVENTION: A 2-mm Amplatz Goose Neck microsnare (Microvena Corp., White Bear Lake, MN) was placed through a Rapid Transit microcatheter (Cordis Corp., Miami, FL). The hub of the indwelling Echelon microcatheter was cut off and the snare advanced over the outside of the microcatheter. The snare and Rapid Transit microcatheter were then advanced into the guiding catheter (6-French) as a unit over the indwelling Echelon microcatheter. Using the adherent Echelon as a "monorail" guide, the snare and Rapid Transit microcatheter were advanced distally into the occipital artery and the snare was retracted to engage the microcatheter. The microcatheters and snare were then easily removed because of the second vector of force placed by the snare system on the adherent microcatheter very close to the point of adherence. CONCLUSION: The monorail snare technique represents a simple and safe way to remove an adherent microcatheter from an Onyx cast during the embolization of dural arteriovenous fistulas. Prospective knowledge of this technique will facilitate more aggressive embolization without the reservation that a retained microcatheter could require surgical removal or anticoagulation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Case report · Consensus signal: Case report
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.001
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0040.002
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.047
GPT teacher head0.284
Teacher spread0.237 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designCase report
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations32
Published2008
Admission routes1
Has abstractyes

Explore more

Same venuePubMedSame topicIntracranial Aneurysms: Treatment and ComplicationsFrench-language works237,207