MétaCan
Menu
Back to cohort
Record W2074319820 · doi:10.1063/1.2938888

Dark current in multilayer amorphous selenium x-ray imaging detectors

2008· article· en· W2074319820 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueApplied Physics Letters · 2008
Typearticle
Languageen
FieldEngineering
TopicAdvanced Semiconductor Detectors and Materials
Canadian institutionsConcordia University
Fundersnot available
KeywordsDark currentDetectorCurrent (fluid)Materials scienceAmorphous solidSchottky barrierSchottky diodeOptoelectronicsTransient (computer programming)X-ray detectorOpticsPhysicsChemistryDiode

Abstract

fetched live from OpenAlex

A theoretical model for describing the bias-dependent transient behavior of dark current in multilayer (n-i-p) amorphous selenium (a-Se) detectors has been developed. The transient dark currents in these detectors are measured and are compared to the proposed dark current model. It has been found that the dark current is mainly controlled by Schottky emission of holes from the metal/a-Se contact. The initial and steady state dark currents are mainly controlled by the barrier height and the trap centers in the n layer, respectively.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.033
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.210
Teacher spread0.198 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it