MétaCan
Menu
Back to cohort
Record W2074765702 · doi:10.1118/1.1289375

A two-step algorithm for predicting portal dose images in arbitrary detectors

2000· article· en· W2074765702 on OpenAlexaff
B McCurdy, Stephen Pistorius

Bibliographic record

VenueMedical Physics · 2000
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsCancerCare ManitobaOccupational and Environmental Medical Association of Canada
Fundersnot available
KeywordsImaging phantomMonte Carlo methodFluenceDetectorDosimetryPhysicsOpticsMedical imagingPhotonAlgorithmNuclear medicineComputer scienceMathematicsArtificial intelligenceStatisticsMedicine

Abstract

fetched live from OpenAlex

Recently, portal imaging systems have been successfully demonstrated in dosimetric treatment verification applications, where measured and predicted images are quantitatively compared. To advance this approach to dosimetric verification, a two-step model which predicts dose deposition in arbitrary portal image detectors is presented. The algorithm requires patient CT data, source-detector distance, and knowledge of the incident beam fluence. The first step predicts the fluence entering a portal imaging detector located behind the patient. Primary fluence is obtained through ray-tracing techniques, while scatter fluence prediction requires a library of Monte Carlo-generated scatter fluence kernels. These kernels allow prediction of basic radiation transport parameters characterizing the scattered photons, including fluence and mean energy. The second step of the algorithm involves a superposition of Monte Carlo-generated pencil beam kernels, describing dose deposition in a specific detector, with the predicted incident fluence. This process is performed separately for primary and scatter fluence, and yields a predicted dose image. A small but noticeable improvement in prediction is obtained by explicitly modeling the off-axis energy spectrum softening due to the flattening filter. The algorithm is tested on a slab phantom and a simple lung phantom (6 MV). Furthermore, an anthropomorphic phantom is utilized for a simulated lung treatment (6 MV), and simulated pelvis treatment (23 MV). Data were collected over a range of air gaps (10-80 cm). Detectors incorporating both low and high atomic number buildup are used to measure portal image profiles. Agreement between predicted and measured portal dose is better than 3% in areas of low dose gradient (<30%/cm) for all phantoms, air gaps, beam energies, and detector configurations tested here. It is concluded that this portal dose prediction algorithm is fast, accurate, allows separation of primary and scatter dose, and can model arbitrary detectors.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.006
Threshold uncertainty score0.012

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0020.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.278
Teacher spread0.272 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations57
Published2000
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207