MétaCan
Menu
Back to cohort
Record W2075142560 · doi:10.1161/01.cir.101.11.1297

Canadian Implantable Defibrillator Study (CIDS)

2000· article· en· W2075142560 on OpenAlexaffabout
Stuart J. Connolly, Michael Gent, Robin S. Roberts, Paul Dorian, Denis‐Claude Roy, Robert S. Sheldon, L. Brent Mitchell, Martin S. Green, George J. Klein, Bernard O’Brien

Bibliographic record

VenueCirculation · 2000
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsUniversity of TorontoMcMaster University
Fundersnot available
KeywordsMedicineAmiodaroneImplantable cardioverter-defibrillatorCardiologyRelative riskInternal medicineConfidence intervalVentricular tachycardiaVentricular fibrillationAtrial fibrillationSudden deathDefibrillationRandomized controlled trialAntiarrhythmic agentAnesthesiaHeart disease

Abstract

fetched live from OpenAlex

BACKGROUND: Patients surviving ventricular fibrillation (VF) or sustained ventricular tachycardia (VT) are at a high risk of death due to a recurrence of arrhythmia. The implantable cardioverter defibrillator (ICD) terminates VT or VF, but it is not known whether this device prolongs life in these patients compared with medical therapy with amiodarone. METHODS AND RESULTS: A total of 659 patients with resuscitated VF or VT or with unmonitored syncope were randomly assigned to treatment with the ICD or with amiodarone. The primary outcome measure was all-cause mortality, and the secondary outcome was arrhythmic death. A total of 328 patients were randomized to receive an ICD. A thoracotomy was done in 33, no ICD was implanted in 18, and the rest had a nonthoracotomy ICD. All 331 patients randomized to amiodarone received it initially. At 5 years, 85.4% of patients assigned to amiodarone were still receiving it at a mean dose of 255 mg/day, 28.1% of ICD patients were also receiving amiodarone, and 21.4% of amiodarone patients had received an ICD. A nonsignificant reduction in the risk of death was observed with the ICD, from 10.2% per year to 8.3% per year (19.7% relative risk reduction; 95% confidence interval, -7.7% to 40%; P=0.142). A nonsignificant reduction in the risk of arrhythmic death was observed, from 4.5% per year to 3.0% per year (32.8% relative risk reduction; 95% confidence interval, -7.2% to 57.8%; P=0.094). CONCLUSIONS: A 20% relative risk reduction occurred in all-cause mortality and a 33% reduction occurred in arrhythmic mortality with ICD therapy compared with amiodarone; this reduction did not reach statistical significance.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.356
Threshold uncertainty score0.716

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.002
Science and technology studies0.0020.001
Scholarly communication0.0010.000
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0090.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.273
Teacher spread0.256 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1,602
Published2000
Admission routes2
Has abstractyes

Explore more

Same venueCirculationSame topicCardiac pacing and defibrillation studiesFrench-language works237,207