Microfabricated Device for DNA and RNA Amplification by Continuous-Flow Polymerase Chain Reaction and Reverse Transcription-Polymerase Chain Reaction with Cycle Number Selection
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
We have developed a high-throughput microfabricated, reusable glass chip for the functional integration of reverse transcription (RT) and polymerase chain reaction (PCR) in a continuous-flow mode. The chip allows for selection of the number of amplification cycles. A single microchannel network was etched that defines four distinct zones, one for RT and three for PCR (denaturation, annealing, extension). The zone temperatures were controlled by placing the chip over four heating blocks. Samples and reagents for RT and PCR were pumped continuously through appropriate access holes. Outlet channels were etched after cycles 20, 25, 30, 35, and 40 for product collection. The surface-to-volume ratio for the PCR channel is 57 mm(-1) and the channel depth is 55 microm, both of which allow very rapid heat transfer. As a result, we were able to collect PCR product after 30 amplification cycles in only 6 min. Products were collected in 0.2-mL tubes and analyzed by agarose gel electrophoresis and ethidium bromide staining. We studied DNA and RNA amplification as a function of cycle number. The effect of the number of the initial DNA and RNA input molecules was studied in the range of 2.5 x 10(6) - 1.6 x 10(8) and 6.2 x 10(6) - 2 x 10(8), respectively. Successful amplification of a single-copy gene (beta-globin) from human genomic DNA was carried out. Furthermore, PCR was performed on three samples of DNA of different lengths (each of 2-microL reaction volume) flowing simultaneously in the chip, and the products were collected after various numbers of cycles. Reverse transcription was also carried out on four RNA samples (0.7-microL reaction volume) flowing simultaneously in the chip, followed by PCR amplification. Finally, we have demonstrated the concept of manually pumped injection and transport of the reaction mixture in continuous-flow PCR for the rapid generation of amplification products with minimal instrumentation. To our knowledge, this is the first report of a monolithic microdevice that integrates continuous-flow RT and PCR with cycle number selection.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it