MétaCan
Menu
Back to cohort
Record W2077435164 · doi:10.1128/jcm.44.3.725-728.2006

Sensitivities of Antigen Detection and PCR Assays Greatly Increased Compared to That of the Standard Culture Method for Screening for Group B Streptococcus Carriage in Pregnant Women

2006· article· en· W2077435164 on OpenAlexaff
Fabien Rallu, Peter Barriga, Carole Scrivo, Valérie Martel‐Laferrière, Céline Laferrière

Bibliographic record

VenueJournal of Clinical Microbiology · 2006
Typearticle
Languageen
FieldMedicine
TopicNeonatal and Maternal Infections
Canadian institutionsCentre Hospitalier Universitaire Sainte-Justine
Fundersnot available
KeywordsStreptococcusCarriageGroup BAntigenMicrobiologyMedicineContext (archaeology)ColistinStreptococcus agalactiaeBiologyAntibioticsImmunologyInternal medicineBacteriaPathology

Abstract

fetched live from OpenAlex

Group B streptococcus (GBS) is a major cause of serious infections in neonates. The 2002 revised guidelines of the Centers for Disease Control and Prevention (CDC) for the prevention of perinatal GBS disease recommend that all pregnant women be screened for GBS carriage at between 35 and 37 weeks of gestation and that intrapartum antibiotic prophylaxis be given to carriers. We studied the performances of four different GBS detection assays in the context of antenatal screening. Between May and August 2004, the 605 vaginorectal swab specimens received at our bacteriology laboratory for GBS antenatal detection were tested by the four assays. The standard culture method was done according to the CDC recommendations. The three experimental assays performed with the growth from the selective enrichment (LIM) broth (Todd-Hewitt broth with 15 mug/ml nalidixic acid and 10 mug/ml colistin) after overnight incubation were a GBS antigen detection assay (PathoDx) and two PCR assays (for cfb and scpB). The most accurate assay was the scpB PCR (sensitivity, 99.6%; specificity, 100%), followed by the cfb PCR (sensitivity, 75.3%; specificity, 100%), GBS antigen detection (sensitivity, 57.3%; specificity, 99.5%), and standard culture (sensitivity, 42.3%; specificity, 100%). The GBS antigen detection assay was found to be more sensitive than the standard culture method, and moreover, the assay has a low cost and is easy to perform in all obstetrical centers which have access to the most basic of diagnostic microbiology services. We believe that antigen detection on incubated LIM broth should replace the standard culture method for screening for GBS carriage at 35 to 37 weeks of gestation. The impact of the greater sensitivities of PCR assays on the diminution of neonatal GBS infections remains to be demonstrated.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.013
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.034

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0060.013
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.002
Insufficient payload (model declined to judge)0.0020.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.046
GPT teacher head0.367
Teacher spread0.321 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations105
Published2006
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Clinical MicrobiologySame topicNeonatal and Maternal InfectionsFrench-language works237,207