MétaCan
Menu
Back to cohort

A Comparison of Two Methods of Enhancing Implant Primary Stability

2004· article· en· W2077828386 on OpenAlexvenueno aff
Dominic O’Sullivan, Lars Sennerby, Daryll C Jagger, Neil Meredith

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2004
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsResonance frequency analysisImplantImplant stability quotientDentistryOsseointegrationSignificant differenceMedicineMaterials scienceOrthodonticsSurgery

Abstract

fetched live from OpenAlex

BACKGROUND: Surgical technique and implant design have an effect on the primary stability of oral implants, which in turn increases resistance to implant micromotion during healing. PURPOSE: This study was designed to compare the parameters associated with implant insertion using two different methods of enhancing implant primary stability and to identify any relationship between these parameters and changes in the stability of implants during the initial 6-month healing period following implant insertion. A comparison was made between two methods of enhancing primary implant stability: method 1, standard Brånemark System implants (Nobel Biocare AB, Gothenburg, Sweden) inserted with a technique designed to enhance primary stability, and method 2: Brånemark Mk IV implants (Nobel Biocare AB) inserted according to the manufacturer's instructions. MATERIALS AND METHODS: Thirteen patients were selected for inclusion in the study. A total of 42 implants were placed. Insertion torque data were recorded, and bone quality at the implant site was assessed at implant insertion. Resonance frequency analysis measurements were taken at implant insertion as well as at second-stage surgery 6 months later. RESULTS: A statistically significant difference was recorded between the mean maximum insertion torque for type 4 bone and bone types 2 and 3. No significant difference was recorded between bone types 2 and 3. A significantly lower resonance frequency value was seen for standard implants placed into type 4 bone (p < .05). Across all implant types a significant difference in the energy required when inserting implants into type 4 bone and bone types 2 and 3 was seen. A significantly lower mean energy requirement was seen between the Mk IV implants placed into type 4 bone and the other combinations of implant types and bone. CONCLUSIONS: Within the limitations of this study, the results agree with the manufacturer's claim that when compared with standard implants, the design of the Mk IV implant increases implant primary stability with a reduction in the energy imparted into the bone at the implant site.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.008
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.096
Threshold uncertainty score0.809

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0080.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0010.001
Research integrity0.0010.002
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.265
GPT teacher head0.591
Teacher spread0.326 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations147
Published2004
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related ResearchSame topicDental Implant Techniques and OutcomesFrench-language works237,207