MétaCan
Menu
Back to cohort
Record W2077951165 · doi:10.1097/brs.0b013e318188b2e4

The Effect of Cement Augmentation and Extension of Posterior Instrumentation on Stabilization and Adjacent Level Effects in the Elderly Spine

2008· article· en· W2077951165 on OpenAlexaff
Juay-Seng Tan, Sandeep Singh, Qingan Zhu, Marcel F. Dvorak, Charles G. Fisher, Thomas R. Oxland

Bibliographic record

VenueSpine · 2008
Typearticle
Languageen
FieldMedicine
TopicSpinal Fractures and Fixation Techniques
Canadian institutionsVancouver General HospitalVancouver Coastal Health Research InstituteUniversity of British Columbia
Fundersnot available
KeywordsCadaveric spasmMedicineCorpectomyFixation (population genetics)Range of motionImplantOrthodonticsBiomechanicsCadaverBiomedical engineeringSurgeryAnatomyDecompression

Abstract

fetched live from OpenAlex

STUDY DESIGN: An in vitro cadaveric study comparing different implant fixation techniques using a repeated measures design. OBJECTIVE: To compare the effects of cement augmentation of pedicle screws and extension of posterior fixation on (i) 3-dimensional stabilization, and (ii) adjacent level effects in the aging spine. SUMMARY OF BACKGROUND DATA: Device loosening and adjacent level effects are concerns in implant fixation in the elderly spine. Extension of posterior fixation and cement augmentation of pedicle screws have not been previously compared with respect to stabilization and adjacent level effects. METHODS: Twelve T9 to L3 cadaveric specimens were tested in flexion-extension (FE), lateral bending (LB), and axial rotation (AR) with applied pure moments of +/-5 Nm. A T11 corpectomy was reconstructed with a vertebral body replacement device and T10 to T12 posterior instrumentation. Further stabilization was provided by posterior rod extension to L1 (flexible or rigid rods) and/or cement augmentation of T12 and L1 screws. The effects of cement augmentation and posterior rod extension on intersegmental motion were compared using the hybrid flexibility-stiffness protocol. Two-way repeated measures ANOVA and SNK post hoc tests (99% significance level) were used. RESULTS: Range of motion at the corpectomy T10 to T12 levels significantly decreased after cement augmentation (AR 43%, LB 71%, FE 68%), and posterior rod extension (rigid rods: AR 26%, LB 64%, FE 57%) (flexible rods: AR 16%, LB 53%, FE 39%). Posterior rod extension significantly reduced range of motion at the rod extension level. Motion at the distal noninstrumented L1 to L2 level was increased significantly by posterior rod extension and cement augmentation. There were however, smaller magnitudes of increase in motion across L1 to L2 level with flexible rod and cement augmentation (AR 12%, LB 45%, FE 31%). CONCLUSION: Cement augmentation of pedicle screws resulted in the most stable vertebral reconstruction, whereas flexible rod extension minimized changes in range of motion at both adjacent rod extension and distal noninstrumented levels.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.733
Threshold uncertainty score0.173

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.304
Teacher spread0.284 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations28
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueSpineSame topicSpinal Fractures and Fixation TechniquesFrench-language works237,207