MétaCan
Menu
← Back to cohort
Record W2078876424 · doi:10.1118/1.4740203

Sci—Fri PM: Delivery — 08: Characterizing the spatially varying fluence and spectra of a kV imaging source for dose calculations

2012· article· en· W2078876424 on OpenAlexaff
Yannick Poirier, Alexei Kouznetsov, Mauro Tambasco

Bibliographic record

VenueMedical Physics · 2012
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsUniversity of Calgary
Fundersnot available
KeywordsFluenceSpectral lineMedical imagingDosimetryMaterials sciencePhysicsOpticsComputational physicsNuclear medicineNuclear physicsIrradiationMedicineRadiology

Abstract

fetched live from OpenAlex

Kilovoltage (kV) daily image‐guided radiotherapy (IGRT) procedures accumulate radiation dose within the patient that is currently not routinely incorporated in the treatment plan. As part of the process of developing a patient‐specific kV dose computation tool, the kV x‐ray source must be characterized. We propose a simple, clinically feasible experimental characterization method using in‐air dose measurements along the transverse axis. We determine half‐value layer (HVL) along the transverse axis, from which we derive the HVL‐specific mass‐absorption coefficient, which is used to determine beam fluence. These values are interpolated over the entire field. The spectrum at each interpolation point in the field is found from HVL and accelerating potential (kVp) using third‐party software Spektr. We use this method to characterize the spatially varying fluence and spectra of a Varian® On‐Board Imaging® source for energies 80, 100 and 125 kVp. This characterization is used to compute dose within a heterogeneous phantom, using our previously validated in‐house dose computation software, which we compare with relative dose measurements. We show that for a 10×10 cm2 field size using no added filtration, the agreement for all three energies is within 2% for the central depth‐dose profile and within 2.6% for the transverse profiles. This clinically feasible experimental characterization method for kV imaging sources represents a crucial step in the development of a patient‐specific dose computation tool.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.286
Threshold uncertainty score0.957

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0010.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.2860.139

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.279
Teacher spread0.266 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueMedical Physics→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→