MétaCan
Menu
Back to cohort
Record W2079292521 · doi:10.1118/1.4740106

Sci-Thur PM: YIS - 09: Development of a graphite probe calorimeter for absolute clinical dosimetry: Numerical design optimization, prototyping and experimental proof-of-concept

2012· article· en· W2079292521 on OpenAlexaff
James Renaud, D Marchington, Jan Seuntjens, Arman Sarfehnia

Bibliographic record

VenueMedical Physics · 2012
Typearticle
Languageen
FieldChemistry
Topicthermodynamics and calorimetric analyses
Canadian institutionsNational Research Council CanadaMcGill University
Fundersnot available
KeywordsDosimeterDosimetryCalorimeter (particle physics)Materials scienceCalibrationAbsorbed doseRepeatabilityMonte Carlo methodThermistorNuclear engineeringOpticsPhysicsNuclear medicineDetectorMathematicsStatisticsEngineering

Abstract

fetched live from OpenAlex

In this work, the feasibility of absolute dose to water measurements using a small-scale graphite probe calorimeter (GPC) in a clinical environment is established. A numerical design optimization study was conducted by simulating the heat transfer in the GPC resulting from irradiation using a finite element method software package. The choice of device shape, dimensions and materials was made to minimize the heat loss in the sensitive volume of the GPC. The resulting design, which incorporates a novel aerogel-based thermal insulator, was built in-house. Absorbed dose to water measurements were made under standard conditions in a 6 MV 1000 MU/min photon beam and subsequently compared against TG-51 derived values. The average measured dose to water was 95.7 ±1.4 cGy/100 MU, as compared to an expected value of 96.6 cGy/100 MU. The Monte Carlo-calculated graphite to water dose conversion factor was 1.099, while the derived heat loss correction factors varied between 1.005 and 1.013. The most significant sources of uncertainty were the repeatability (type A, 1.4%) and thermistor calibration (type B, 2.1%). The contribution of these factors to the overall uncertainty is expected to decrease significantly upon the implementation of active thermal stabilization provided by a temperature controller and direct electrical calibration, respectively. This work demonstrates the feasibility of using the GPC as a practical clinical absolute photon dosimeter and will serve as the basis for a miniaturized version applicable to small and composite fields.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.911
Threshold uncertainty score0.776

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.050
GPT teacher head0.325
Teacher spread0.275 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicthermodynamics and calorimetric analysesFrench-language works237,207