MétaCan
Menu
Back to cohort

Screw Position After Double-Rod Anterior Spinal Fusion in Idiopathic Scoliosis

2006· article· en· W2079472967 on OpenAlexaff
Geertje C. Huitema, Lodewijk W. van Rhijn, André van Ooij

Bibliographic record

VenueSpine · 2006
Typearticle
Languageen
FieldMedicine
TopicSpinal Fractures and Fixation Techniques
Canadian institutionsDiscovery Air (Canada)
Fundersnot available
KeywordsMedicineScoliosisFluoroscopySpinal fusionSurgerySpinal canalIdiopathic scoliosisRadiographyArthrodesisRachisOrthodonticsSpinal cord

Abstract

fetched live from OpenAlex

STUDY DESIGN: A retrospective evaluation of screw position after double-rod anterior spinal fusion in idiopathic scoliosis using computerized tomography (CT). OBJECTIVE: To evaluate screw position and complications related to screw position after double-rod anterior instrumentation in idiopathic scoliosis. SUMMARY OF BACKGROUND DATA: Anterior instrumentation and fusion in idiopathic scoliosis is gaining widespread use. However, no studies have been published regarding the accuracy of screw placement and screw-related complications in double-rod and double-screw anterior spinal fusion and instrumentation in idiopathic thoracolumbar scoliosis surgery. METHODS: CT examinations were performed after surgery in 17 patients with idiopathic scoliosis. At each instrumented level, the position of the screw and the plate relative to the spinal canal, relative to the neural foramen, and relative to the aorta was measured. Complications related to screw position were registered. RESULTS: A total of 189 screws in 17 patients were evaluated. Malposition occurred in 23% (16 patients) of the total number of screws. Three screws (2 patients) were partially in the spinal canal (1%). This resulted in pain in the right leg in 2 patients. However, electromyography showed no abnormalities. At three levels (3 patients), there was contact between the instrumentation and the aorta. However, no vascular complications occurred. A total of 113 screws (10 patients) were placed under fluoroscopic control and 76 screws (7 patients) were placed without use of fluoroscopy. Less screw malposition was observed in the group in which fluoroscopic control was used (19% vs. 30%, not significant). CONCLUSIONS: Screw placement in double-rod anterior spinal fusion in idiopathic scoliosis seems to be technically demanding, and the use of fluoroscopic control results in less frequent malposition. The risk of neurologic and vascular complications is low.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.001
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.285
Teacher spread0.276 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2006
Admission routes1
Has abstractyes

Explore more

Same venueSpineSame topicSpinal Fractures and Fixation TechniquesFrench-language works237,207