MétaCan
Menu
Back to cohort
Record W2079711863 · doi:10.1148/radiol.2542090674

Repeat Prostate Biopsy Accuracy: Simulator-based Comparison of Two- and Three-dimensional Transrectal US Modalities

2010· article· en· W2079711863 on OpenAlexafffund
Derek W. Cool, Michael Connolly, Shi Sherebrin, Roy Eagleson, Jonathan I. Izawa, Justin Amann, Cesare Romagnoli, Walter Romano, Aaron Fenster

Bibliographic record

VenueRadiology · 2010
Typearticle
Languageen
FieldMedicine
TopicProstate Cancer Diagnosis and Treatment
Canadian institutionsWestern University
FundersCanadian Institutes of Health Research
KeywordsBiopsyMedicineProstate biopsyTransrectal ultrasonographyProstateRadiologySampling (signal processing)Prostate cancerUrologyInternal medicineCancerComputer science

Abstract

fetched live from OpenAlex

PURPOSE: To compare the accuracy of biopsy with two-dimensional (2D) transrectal ultrasonography (US) with that of biopsy with conventional three-dimensional (3D) transrectal US and biopsy with guided 3D transrectal US in the guidance of repeat prostate biopsy procedures in a prostate biopsy simulator. MATERIALS AND METHODS: The institutional review board approved this retrospective study. Five residents and five experts performed repeat biopsies with a biopsy simulator that contained the transrectal US prostate images of 10 patients who had undergone biopsy. Simulated repeat biopsies were performed with 2D transrectal US, conventional 3D transrectal US, and guided 3D transrectal US (an extension of 3D transrectal US that enables active display of biopsy targets). The modalities were compared on the basis of time per biopsy and how accurately simulated repeat biopsies could be guided to specific targets. The probability for successful biopsy of a repeat target was calculated for each modality. RESULTS: Guided 3D transrectal US was significantly (P < .01) more accurate for simulated biopsy of repeat targets than was 2D or 3D transrectal US, with a biopsy accuracy of 0.86 mm +/- 0.47 (standard deviation), 3.68 mm +/- 2.60, and 3.60 mm +/- 2.57, respectively. Experts had a 70% probability of sampling a prior biopsy target volume of 0.5 cm(3) with 2D transrectal US; however, the probability approached 100% with guided 3D transrectal US. Biopsy accuracy was not significantly different between experts and residents for any modality; however, experts were significantly (P < .05) faster than residents with each modality. CONCLUSION: Repeat biopsy of the prostate with 2D transrectal US has limited accuracy. Compared with 2D transrectal US, the biopsy accuracy of both experts and residents improved with guided 3D transrectal US but did not improve with conventional 3D transrectal US.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.157
Threshold uncertainty score0.490

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.314
Teacher spread0.294 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations17
Published2010
Admission routes2
Has abstractyes

Explore more

Same venueRadiologySame topicProstate Cancer Diagnosis and TreatmentFrench-language works237,207