MétaCan
Menu
Back to cohort
Record W2079917864 · doi:10.1120/jacmp.v5i4.2012

Dosimetric uncertainties of three‐dimensional dose reconstruction from two‐dimensional data in a multi‐institutional study

2004· article· en· W2079917864 on OpenAlexaff
Rebecca Weinberg, D.G. Kaurin, Hak Choy, Walter J. Curran, Robert M. MacRae, Kim Js, Jaechul Kim, Susan L. Tucker, Philip Bonomi, Chandra P. Belani, George Starkschall

Bibliographic record

VenueJournal of Applied Clinical Medical Physics · 2004
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsOttawa Regional Cancer Foundation
FundersNational Cancer InstituteVanderbilt University Medical CenterVanderbilt UniversityBristol-Myers Squibb
KeywordsContouringMedicineRadiation treatment planningNuclear medicineMedical physicsProtocol (science)Quality assuranceData setRadiologyRadiation therapyComputer scienceArtificial intelligencePathology

Abstract

fetched live from OpenAlex

Inconsistencies in the treatment planning process leading to dosimetric uncertainties may affect conclusions drawn from interinstitutional radiation oncology clinical trials. The purpose of this study was to assess the dosimetric uncertainties resulting from the process of reconstructing three-dimensional dose distributions from two-dimensional treatment plan information provided by participating institutions in a randomized clinical trial. This study was based on American College of Radiology Protocol #427, Locally Advanced Multi-Modality Protocol; a multi-institutional phase II randomized study involving radiation therapy for patients with inoperable non-small cell lung cancer. Several sources of dosimetric uncertainty were identified and analyzed, including image quality of hard-copy computed tomography (CT) images, slice spacing of CT scans, treatment position, interpretations of target volumes by radiation oncologists, the contouring of normal anatomic structures, and the use of common beam models for all dose calculations. Each source of uncertainty was investigated using a set of plans, with the ideal characteristics of digital images with 3-mm axial slice spacing and a flat couch, consisting of eight cases from Vanderbilt University Medical Center with electronically transferred CT data. The target volume DVH values were dependent on the additional uncertainty introduced by differences in delineation of the target volumes by the participating radiation oncologists. The DVH values for the lungs and heart were dependent on image quality and treatment position. Esophagus DVH values were not dependent on any of the sources of uncertainty. None of the structure DVH values were dependent on slice thickness or variations in the contouring of normal anatomic structures. Reconstruction of three-dimensional dose distributions from two-dimensional treatment plan information may be useful in cases for which digital CT data is not available or for historical data review. However, dosimetric accuracy will depend on image quality of the treatment planning CT data and consistency in the delineation of tumor volumes.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.120
metaresearch head score (Gemma)0.204
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.120
Threshold uncertainty score0.637

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.1200.204
Meta-epidemiology (narrow)0.0000.001
Meta-epidemiology (broad)0.0010.002
Bibliometrics0.0010.002
Science and technology studies0.0010.002
Scholarly communication0.0020.001
Open science0.0010.002
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.065
GPT teacher head0.385
Teacher spread0.320 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2004
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Applied Clinical Medical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207