MétaCan
Menu
← Back to cohort
Record W2080848961 · doi:10.1118/1.2241498

TU‐C‐330A‐05: Optimization of Outer Volume Suppression for Improved Prostate MR Spectroscopic Imaging

2006· article· en· W2080848961 on OpenAlexaff
Niranjan Venugopal, Boyd McCurdy, Lawrence Ryner

Bibliographic record

VenueMedical Physics · 2006
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsNational Research Council CanadaNational Research Council Institute for BiodiagnosticsUniversity of ManitobaCancerCare Manitoba
Fundersnot available
KeywordsVoxelProstateSIGNAL (programming language)Imaging phantomContaminationNuclear magnetic resonanceMaterials scienceSpectral lineNuclear medicinePhysicsMedicineComputer scienceRadiologyBiologyInternal medicine

Abstract

fetched live from OpenAlex

Purpose: To adapt a new MR Spectroscopy (MRS) technique employing non‐cuboidal voxels, called conformal voxel MRS (CV‐MRS), for use in prostate spectroscopic imaging in order to reduce contamination of spectra by lipid signal surrounding the prostate. Method and Materials: CV‐MRS uses twenty or more spatial saturation (SS) pulses, placed around the prostate, to reduce the lipid signal affecting the spectra within the prostate. A water/oil phantom was designed to simulate the prostate and surrounding lipid signal. Use of the new CV‐MRS technique reduced the lipid signal contamination by 84% as compared to standard cuboidal voxel MRS. To further reduce the lipid contamination, the routinely used 90 degree flip angle used for each SS pulse was modified to take into account the regrowth of lipid signal with its short T1 relaxation time. Results: Contrary to our expectations, resulting spectra from the optimized approach actually showed an increase in lipid contamination by 10%. We tracked the problem down to overlapping SS pulses. Using a simulated 3D model, we found that 68% of the volume we were trying to saturate experienced multiple overlapping SS pulses, with some regions being saturated 7 or more times. Regions of the volume experiencing an even number of SS pulses were found to increase the lipid contamination signal by 88% to 200%. Conversely, regions experiencing an odd number of SS pulses had a reduction in lipid contamination of 55%. Conclusion: Changing the ordering of the SS pulses, such that the overlapping pulses occur later in the train of 20 SS pulses reduced the problem of lipid signal from those overlapping volumes. In summary, we have developed an improved outer volume saturation technique which reduces lipid contamination problems in prostate MR spectroscopic imaging.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.295
Teacher spread0.288 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2006
Admission routes1
Has abstractyes

Explore more

Same venueMedical Physics→Same topicAdvanced MRI Techniques and Applications→French-language works237,207→