Solids Circulation Flux and Gas Bypassing in a Pressurized Spout‐fluid Bed with a Draft Tube
Bibliographic record
Abstract
Abstract An experimental study on solids circulation flux and gas bypassing of a spout‐fluid bed with a draft tube at elevated pressures up to 600 kPa was performed in a 200 mm diameter cylindrical steel column with a 608 conical distributor. Glass beads with mean diameter 2.067 mm were used as bed materials to investigate the effect of operating conditions and geometric configuration on the solids circulation flux and the gas distribution between the annulus and the draft tube. A novel technique has been developed to measure the solids fluxes under pressure, and gas (CO2) traces have been employed to investigate gas bypassing characteristics. The solids circulation flux is greatly enhanced when operating pressure and auxiliary gas flowrate are increased, and it is also strongly influenced by geometric configuration. Two experimental relations are proposed for predicting solids circulation flux enhancement factors.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.001 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.001 | 0.001 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".