MétaCan
Menu
Back to cohort
Record W2081563352 · doi:10.1121/1.4877211

Passive mapping of acoustic sources within the human skull cavity with a hemispherical sparse array using computed tomography-based aberration corrections

2014· article· en· W2081563352 on OpenAlexaff
Ryan M. Jones, Meaghan A. O’Reilly, Kullervo Hynynen

Bibliographic record

VenueThe Journal of the Acoustical Society of America · 2014
Typearticle
Languageen
FieldEngineering
TopicUltrasound and Hyperthermia Applications
Canadian institutionsSunnybrook Health Science CentreUniversity of Toronto
Fundersnot available
KeywordsHydrophoneBeamformingPhased arrayAcousticsTranscranial DopplerTomographyTransducerUltrasoundSkullComputer scienceSparse arrayMaterials scienceOpticsBiomedical engineeringPhysicsRadiologyGeologyAntenna (radio)MedicineTelecommunications

Abstract

fetched live from OpenAlex

Traditionally, the use of ultrasound (US) in the brain has been limited by the skull bone, which presents unique challenges for both transcranial therapy and imaging due to its attenuating and aberrating effects, which become more prevalent at higher US frequencies. On transmit, these skull-induced aberrations can be overcome through the use of large-aperture phased array transducers with appropriate driving frequencies, combined with computed tomography (CT)-based bone morphology and numerical models to derive element driving signals which minimize the distortions. Recently, we have demonstrated in silico that an analogous approach can be performed during beamforming on receive, to allow for passive acoustic imaging over a large region within the skull cavity [Jones et al., Phys. Med. Biol. 58, 4981–5005 (2013)]. We will present preliminary results obtained from applying this technique experimentally with a hemispherical (30 cm diam.) sparse receiver array (128 piezo-ceramic elements, 2.5 mm diam., and 612 kHz center frequency) to image acoustic sources through an ex vivo human skullcap. Images produced using non-invasive CT-based skull corrections will be compared with those obtained through an invasive hydrophone-based correction approach, and with images formed without skull-specific corrections. This technique has promising applications in both cavitation-mediated transcranial focused ultrasound therapies, by providing a method for treatment monitoring and control, as well as in ultrasound angiographic imaging of the brain.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.214
Teacher spread0.203 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2014
Admission routes1
Has abstractyes

Explore more

Same venueThe Journal of the Acoustical Society of AmericaSame topicUltrasound and Hyperthermia ApplicationsFrench-language works237,207