MétaCan
Menu
Back to cohort
Record W2083150427 · doi:10.1016/j.jmpt.2012.09.011

Reliability and Measurement Error of 3-Dimensional Regional Lumbar Motion Measures: A Systematic Review

2012· review· en· W2083150427 on OpenAlexaff
Rune Mygind Mieritz, Gert Brønfort, Greg Kawchuk, Alan Breen, Jan Hartvigsen

Bibliographic record

VenueJournal of Manipulative and Physiological Therapeutics · 2012
Typereview
Languageen
FieldMedicine
TopicSpine and Intervertebral Disc Pathology
Canadian institutionsSpinal Cord Injury AlbertaUniversity of Alberta
Fundersnot available
KeywordsChecklistReliability (semiconductor)MedicineData extractionReproducibilityObservational errorPopulationStandard errorMEDLINEStatisticsMedical physicsPhysical therapyPhysical medicine and rehabilitationPsychology

Abstract

fetched live from OpenAlex

OBJECTIVE: The purpose of this study was to systematically review the literature on reproducibility (reliability and/or measurement error) of 3-dimensional (3D) regional lumbar motion measurement systems. METHODS: Electronic searches were performed in PubMed, Cumulative Index of the Nursing and Allied Health Literature, Embase, and Mantis databases. To be included, original studies had to report on the reproducibility of a 3D computerized regional lumbar spinal motion analysis system in human subjects. A detailed checklist was developed based on guidelines for reporting reliability and agreement studies, the standards for reporting of diagnostic accuracy, and quality assessment of diagnostic accuracy studies and used for data extraction and quality assessment. The checklist consisted of descriptive items divided into 4 domains: study population, testing circumstances, equipment, and data analysis and presentation. The descriptive items were used as foundation for the quality assessment reflecting the reporting level of the included articles. RESULTS: A total of 15 articles were included in this study. We found incomplete reporting in 1 or more domains in all articles. A varying amount of measurement error was reported in 8 of the 15 articles. Because of incomplete reporting, these reliability and measurement error estimates are difficult to interpret. CONCLUSIONS: The current literature on the reliability and measurement error of measures created by regional 3D spinal instruments contains uncertainties especially in relevant clinical populations. There is uncertainty with respect to the degree that repeated measurements by 3D regional spinal motion instruments are reproducible. However, limited to the studies where reliability estimates were provided, most instruments used under standardized conditions may be considered reliable enough to be used for research purposes on the group level, but it is uncertain if they can be used on the individual patient level.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.100
metaresearch head score (Gemma)0.341
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Systematic review · Consensus signal: Systematic review
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.100
Threshold uncertainty score0.529

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.1000.341
Meta-epidemiology (narrow)0.0020.003
Meta-epidemiology (broad)0.0130.010
Bibliometrics0.0280.019
Science and technology studies0.0010.003
Scholarly communication0.0050.006
Open science0.0040.003
Research integrity0.0030.002
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.663
GPT teacher head0.434
Teacher spread0.230 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSystematic review
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations24
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Manipulative and Physiological TherapeuticsSame topicSpine and Intervertebral Disc PathologyFrench-language works237,207