Radiochromic leuco dye micelle hydrogels: II. Low diffusion rate leuco crystal violet gel
Bibliographic record
Abstract
Radiation-sensitive hydrogels offer the capability of verifying intricate dose distributions in three-dimensional (3D) space conveniently in a single measurement with sub-millimetre spatial resolution. In this study, a new radiochromic hydrogel called leuco crystal violet (LCV) micelle gel is introduced. Upon irradiation, LCV converts to crystal violet (CV(+)). Triton X-100 micelles are used to provide the required hybrid-interfacing environment to dissolve LCV. The diffusion coefficient of the LCV gel has been measured to be 0.036 +/- 0.001 mm(2) h(-1), which is a factor of 25 times less than the standard radiochromic ferrous xylenol-orange (FX) gel; LCV gels without Triton X-100 micelles have a diffusion coefficient of 0.33 +/- 0.02 mm(2) h(-1). The LCV gel formulation contains: 1 mM LCV, 25 mM trichloroacetic acid, 4 mM Triton X-100 and 4% w/w gelatin. The primary innovative feature of this 3D hydrogel is that the radiation-induced CV(+) dye is more soluble in the Triton X-100 micelles than in the surrounding water which consequently leads to more stable post-irradiation dose distributions. A dosimetric characterization revealed that the dose response is reproducible to within 1% over three separate batches, independent of energy, dose rate and dose fractionation but is affected by the temperature ( approximately 4% per degree C) during irradiation. LCV micelle gels scanned optically with a yellow light source are a promising system for 3D dose verification. They may prove to be, especially, useful for scanning large volume dosimeters (i.e. 20 cm) since they are easily manufactured, transparent and near colourless prior to irradiation.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".