MétaCan
Menu
Back to cohort
Record W2083474469 · doi:10.1088/0031-9155/54/22/003

Radiochromic leuco dye micelle hydrogels: II. Low diffusion rate leuco crystal violet gel

2009· article· en· W2083474469 on OpenAlexafffund
Steven Babic, Jerry Battista, Kevin Jordan

Bibliographic record

VenuePhysics in Medicine and Biology · 2009
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsLondon Health Sciences CentreWestern University
FundersCanadian Institutes of Health Research
KeywordsCrystal violetMaterials scienceMicelleIrradiationDosimeterSelf-healing hydrogelsXylenol orangeDiffusionAnalytical Chemistry (journal)Nuclear chemistryChemistryRadiationChromatographyOpticsAqueous solutionPolymer chemistryPhysics

Abstract

fetched live from OpenAlex

Radiation-sensitive hydrogels offer the capability of verifying intricate dose distributions in three-dimensional (3D) space conveniently in a single measurement with sub-millimetre spatial resolution. In this study, a new radiochromic hydrogel called leuco crystal violet (LCV) micelle gel is introduced. Upon irradiation, LCV converts to crystal violet (CV(+)). Triton X-100 micelles are used to provide the required hybrid-interfacing environment to dissolve LCV. The diffusion coefficient of the LCV gel has been measured to be 0.036 +/- 0.001 mm(2) h(-1), which is a factor of 25 times less than the standard radiochromic ferrous xylenol-orange (FX) gel; LCV gels without Triton X-100 micelles have a diffusion coefficient of 0.33 +/- 0.02 mm(2) h(-1). The LCV gel formulation contains: 1 mM LCV, 25 mM trichloroacetic acid, 4 mM Triton X-100 and 4% w/w gelatin. The primary innovative feature of this 3D hydrogel is that the radiation-induced CV(+) dye is more soluble in the Triton X-100 micelles than in the surrounding water which consequently leads to more stable post-irradiation dose distributions. A dosimetric characterization revealed that the dose response is reproducible to within 1% over three separate batches, independent of energy, dose rate and dose fractionation but is affected by the temperature ( approximately 4% per degree C) during irradiation. LCV micelle gels scanned optically with a yellow light source are a promising system for 3D dose verification. They may prove to be, especially, useful for scanning large volume dosimeters (i.e. 20 cm) since they are easily manufactured, transparent and near colourless prior to irradiation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.711
Threshold uncertainty score0.762

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.044
GPT teacher head0.341
Teacher spread0.297 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations113
Published2009
Admission routes2
Has abstractyes

Explore more

Same venuePhysics in Medicine and BiologySame topicAdvanced Radiotherapy TechniquesFrench-language works237,207