MétaCan
Menu
Back to cohort

Stunned peri-infarct canine myocardium is characterized by degradation of troponin T, not troponin I

2004· article· en· W2084239942 on OpenAlexaff
D COLANTONIO

Bibliographic record

VenueCardiovascular Research · 2004
Typearticle
Languageen
FieldMedicine
TopicAcute Myocardial Infarction Research
Canadian institutionsQueen's University
Fundersnot available
KeywordsCardiologyIschemiaTroponin ITroponin complexMedicineInternal medicineMyocardial infarctionTroponinTroponin TInfarctionCoronary occlusion

Abstract

fetched live from OpenAlex

OBJECTIVE: Degradation of cardiac troponin I (cTnI) has been proposed to represent the underlying molecular mechanism responsible for post-ischemic contractile dysfunction of viable but 'stunned' myocardium. However, this concept is largely derived from models of brief, sublethal ischemia essentially devoid of necrosis, and there is speculation that defects in cTnI may be model-dependent. Accordingly, our primary aim was to evaluate the integrity of cardiac troponins-i.e., cTnI, as well as cTnT and cTnC-in viable but stunned peri-infarct tissue. In addition, we addressed the as-yet unexplored issue of whether the profound reduction of infarct size evoked by brief preconditioning ischemia (PC) was accompanied by a favorable attenuation in ischemia/reperfusion-induced degradation of cTnI, cTnT or cTnC in the remaining viable subepicardium. METHODS: Anesthetized open-chest dogs received 10 min of PC ischemia or a comparable control period, followed by 1 h of sustained coronary occlusion and 3 h of reperfusion. Subepicardial biopsies from the center of the soon-to-be ischemic territory were obtained at baseline and at 30 min and 3 h post-reflow, and myofilament protein integrity (intact cTnI, cTnT and cTnC, as well as degradation bands and covalent complexes) were assessed by Western immunoblotting. In addition, in all dogs, wall thickening was measured by echocardiography, collateral blood flow was assessed during sustained occlusion by injection of radiolabeled microspheres, and infarct size was delineated by tetrazolium staining. RESULTS: Although PC was, as expected, cardioprotective (infarct size of 2 +/- 1% of the risk region vs. 17 +/- 6% in controls; p < 0.05), both control and PC groups exhibited profound and comparable contractile dysfunction following reflow (mean wall thickening reduced to 20-22% of baseline values). There was, however, no significant degradation of cTnI in the viable but stunned, peri-infarct tissue. We did observe degradation of cTnT in the stunned subepicardium, an effect that was attenuated in dogs that received antecedent PC ischemia. However, there was no correlation between post-ischemic wall thickening and the immunoreactivity of the intact cTnT band, or wall thickening and the intensity of the cTnT degradation products. CONCLUSIONS: Our results suggest cTnI degradation is not a universal determinant of post-ischemic myocardial stunning. Moreover, the dissociation between cTnT degradation and wall thickening argue against a direct 'cause-and-effect' relationship between proteolysis of cTnT and acute, post-ischemic contractile dysfunction of stunned peri-infarct myocardium.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.005
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.480
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0050.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0020.002
Bibliometrics0.0010.002
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.062
GPT teacher head0.350
Teacher spread0.288 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations37
Published2004
Admission routes1
Has abstractyes

Explore more

Same venueCardiovascular ResearchSame topicAcute Myocardial Infarction ResearchFrench-language works237,207