MétaCan
Menu
← Back to cohort
Record W2085262736 · doi:10.1118/1.2240906

SU‐FF‐J‐130: Validation of Non‐Linear Image Registration‐Based Correction Method for Motion Artifacts in 4D‐CT

2006· article· en· W2085262736 on OpenAlexaff
Emily Heath, Paul Keall, D. Louis Collins, F DeBlois, Jan Seuntjens

Bibliographic record

VenueMedical Physics · 2006
Typearticle
Languageen
FieldMedicine
TopicMedical Imaging Techniques and Applications
Canadian institutionsMontreal General Hospital
Fundersnot available
KeywordsArtifact (error)Interpolation (computer graphics)Artificial intelligenceImaging phantomComputer visionImage registrationComputer scienceLinear interpolationBreathingIterative reconstructionWeightingImage qualityTransformation (genetics)Motion (physics)MathematicsImage (mathematics)Nuclear medicinePattern recognition (psychology)MedicineRadiology

Abstract

fetched live from OpenAlex

Purpose: Motion artifacts in CT can be reduced by using 4D‐CT acquisition techniques where image slices are retrospectively binned according to breathing phase as determined by a breathing trace. However, motion artifacts may still occur due to breathing irregularities. Such artifacts affect organ delineation and lead to complications when using 4D CT data for dose calculation and accumulation. We propose a method for correcting such artifacts by temporal interpolation using non‐linear image registration. Method and Materials: The ANIMAL non‐linear image registration algorithm was used to determine the transformation between artifact‐free phases adjacent to the phase containing the motion artifacts. The weighting factor which, when applied to the transformation, most closely reconstructs the anatomy at the phase to be corrected was determined. CT values in regions of the image containing the artifacts were then replaced with the corresponding CT values from the reconstructed image. The accuracy of the temporal interpolation method was evaluated by simulating motion artifacts resulting from different breathing amplitudes using the NCAT numerical breathing phantom for which the artifact‐free image is available by definition. The reconstructed image was compared to the artifact‐free image. The temporal interpolation method was applied to correct motion artifacts in patient 4D CT data and the corrected images were compared to physician‐delineated contours. Results: Correlation between the NCAT phantom images with and without artifacts was improved from 0.971 to 0.992 after correction of the artifacts by temporal interpolation. The quality of the patient 4D CT data was improved after temporal interpolation and the reconstructed anatomy was consistent with manual contours. Conclusion: We have developed a method for reconstructing anatomy on 4D CT images in the presence of motion artifacts. The temporal interpolation method was demonstrated to reduce the appearance of these artifacts and therefore improve the accuracy of organ delineation and dose calculation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.010
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.004
Threshold uncertainty score0.023

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.010
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.031
GPT teacher head0.372
Teacher spread0.341 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2006
Admission routes1
Has abstractyes

Explore more

Same venueMedical Physics→Same topicMedical Imaging Techniques and Applications→French-language works237,207→