MétaCan
Menu
Back to cohort
Record W2085363380 · doi:10.1021/ac401799z

Step-Scan IR Spectroelectrochemistry with Ultramicroelectrodes: Nonsurface Enhanced Detection of Near Femtomole Quantities Using Synchrotron Radiation

2013· article· en· W2085363380 on OpenAlexafffund
Scott M. Rosendahl, Ferenc Borondics, Tim May, Ian J. Burgess

Bibliographic record

VenueAnalytical Chemistry · 2013
Typearticle
Languageen
FieldChemistry
TopicElectrochemical Analysis and Applications
Canadian institutionsCanadian Light Source (Canada)University of Saskatchewan
FundersCanadian Institutes of Health Research
KeywordsChemistrySynchrotron radiationSynchrotronAnalytical Chemistry (journal)UltramicroelectrodeElectrochemistryOpticsElectrodeChromatographyCyclic voltammetryPhysical chemistry

Abstract

fetched live from OpenAlex

The result of interfacing step-scan spectroelectrochemistry with an IR microscope and synchrotron infrared (SIR) radiation is provided here. An external reflectance cell containing a 25 μm gold ultramicroelectrode is employed to achieve an electrochemical time constant less than one microsecond. The use of a prototypical electrochemical system, i.e., the mass-transport controlled reduction of ferricyanide, allows for a proof of principle evaluation of the viability of SIR for step-scan spectroelectrochemistry. An analysis of the importance of accounting for synchrotron source variation over the prolonged duration of a step-scan experiment is provided. Modeling of the material flux in the restricted diffusion space afforded by the external reflectance cell allows the quantitative IR results to be compared to theoretical predictions. The results indicate that only at very short times does linear diffusion within the cavity dominate the electrode response and the majority of the transient signal operates under conditions of quasi-hemispherical diffusion. The analytical information provided by the IR signal is found to be considerably less than that derived from the current response due the latter's pronounced edge effects. The results provide a detection limit of 36 fmol for step-scan SIR measurements of ferrocyanide. Implications for future IR spectroelectrochemical studies in the microsecond domain are discussed.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.005
GPT teacher head0.220
Teacher spread0.214 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations21
Published2013
Admission routes2
Has abstractyes

Explore more

Same venueAnalytical ChemistrySame topicElectrochemical Analysis and ApplicationsFrench-language works237,207