MétaCan
Menu
Back to cohort
Record W2085382953 · doi:10.1118/1.3352785

Localization of spherical lesions in tumor-mimicking phantoms by 3D sparse array photoacoustic imaging

2010· article· en· W2085382953 on OpenAlexafffund
Pinhas Ephrat, Genevieve C. Albert, Michael Roumeliotis, Michelle Belton, Frank S. Prato, Jeffrey J. L. Carson

Bibliographic record

VenueMedical Physics · 2010
Typearticle
Languageen
FieldEngineering
TopicPhotoacoustic and Ultrasonic Imaging
Canadian institutionsLawson Health Research InstituteSt Joseph's Health CareWestern University
FundersNatural Sciences and Engineering Research Council of CanadaWestern University
KeywordsMaterials scienceContext (archaeology)Photoacoustic imaging in biomedicineBiomedical engineeringMedical imagingOpticsBreast imagingHomogeneousMammographyComputer sciencePhysicsArtificial intelligenceMedicineGeology

Abstract

fetched live from OpenAlex

PURPOSE: The authors have developed a sparse-array photoacoustic imaging (SPAI) system that is capable of mapping 3D distributions of optical absorption using a small number of laser pulses with no mechanical scanning needed. In previous studies, the authors have shown the localization accuracy and the high frame-rate image acquisition on simple phantoms with limited medical relevance. The purpose of this study was to test the imaging capabilities of SPAI in the context of breast tumor detection and localization. METHODS: The authors constructed an array of phantoms that include spherical lesions of sizes 1.5-9 mm, buried in highly scattering tissue phantoms at depths of 3-30 mm. The authors investigated both homogeneous lesions made of blood at varying concentrations and heterogeneous lesions containing vessel-like structures. Volumetric images of the deeply buried lesions were taken at increasingly shallower depths and image-based localization was compared to measured depth. RESULTS: The authors were able to detect and accurately localize homogeneous lesions having a realistic absorption coefficient of 0.2 cm(-1) down to depths of 9-20 mm, and heterogeneous lesions containing 0.5 mm diameter vessel-like structures down to depths of 13-20 mm. Image acquisition required 2.5 s for each volumetric lesion image. CONCLUSIONS: These results suggest that 3D SPAI can detect highly vascularized lesions well below 1 cm in diameter and can overcome optical scatter of tissue to depths of 1-2 cm. With further improvement in the sensitivity and noise characteristics of the imaging system, similar imaging depths should be within reach in real breast tissue. The method, due to its optical contrast, 3D imaging, and fast acquisition, may prove useful in the clinic as an adjunct to existing breast screening tools.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.888
Threshold uncertainty score0.751

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.219
Teacher spread0.213 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations14
Published2010
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicPhotoacoustic and Ultrasonic ImagingFrench-language works237,207