MétaCan
Menu
Back to cohort
Record W2085925628 · doi:10.1002/jmri.21107

Accuracy and reliability of MRI vs. laboratory measurements in an ex vivo porcine model of arthritic cartilage loss

2007· article· en· W2085925628 on OpenAlexaff
Jacob L. Jaremko, Conrad M. Maciejewski, Rita W. T. Cheng, Janet L. Ronsky, Richard B. Thompson, R. Lambert, Sukhvinder Dhillon

Bibliographic record

VenueJournal of Magnetic Resonance Imaging · 2007
Typearticle
Languageen
FieldMedicine
TopicOsteoarthritis Treatment and Mechanisms
Canadian institutionsUniversity of CalgaryUniversity of Alberta
Fundersnot available
KeywordsCartilageEx vivoMagnetic resonance imagingVolume (thermodynamics)Coefficient of variationKnee cartilageNuclear medicineIn vivoBiomedical engineeringArticular cartilageOsteoarthritisAnatomyMedicineChemistryRadiologyPathologyBiologyPhysicsChromatography

Abstract

fetched live from OpenAlex

PURPOSE: To quantify the accuracy of magnetic resonance imaging (MRI) measurement of change in cartilage volume due to thin linear excisions, simulating arthritic cartilage losses, by comparison with laboratory volume measurements in an ex vivo porcine model. MATERIALS AND METHODS: We scanned 15 porcine patellae by T1-weighted spoiled gradient echo (SPGR) MRI at baseline and after excision of up to three thin layers of articular cartilage. Excised fragment volume was determined from density and weight. Postexcision scans were "fused" to the baseline scan by three-dimensional (3D) registration. This allowed automated recalculation of the remaining cartilage volume within a baseline region of interest (ROI) following each excision. We compared MRI estimates of change in cartilage volume to direct laboratory measurement of fragment volume. RESULTS: Our 38 excised fragments averaged 0.16 mL, or approximately 7% of cartilage volume. MRI and laboratory estimates of total cartilage volume loss differed by 1.6% +/- 13.2% (mean, coefficient of variation [CV]). Accuracy was +/-0.1 mL for 95% of scans. CONCLUSION: MRI estimates of small changes in porcine patellar cartilage volume were unbiased, reliable, and accurate to 0.1 mL. Despite a proportionately high error in the very thin fragments tested, achievement of similar accuracy in vivo would be adequate to detect approximately two years of osteoarthritic cartilage loss.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.013
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.020

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.013
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.278
Teacher spread0.261 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2007
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Magnetic Resonance ImagingSame topicOsteoarthritis Treatment and MechanismsFrench-language works237,207