MétaCan
Menu
Back to cohort
Record W2086318393 · doi:10.1115/ht2013-17547

Experimental Study of a Closed-Loop Thermosyphon Operating With Slurries of a Microencapsulated Phase-Change Material

2013· article· en· W2086318393 on OpenAlexafffund
Alexandre Lamoureux, B. R. Baliga

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldEngineering
TopicHeat Transfer and Boiling Studies
Canadian institutionsMcGill University
FundersFonds Québécois de la Recherche sur la Nature et les TechnologiesNatural Sciences and Engineering Research Council of CanadaMcGill University
KeywordsMaterials scienceThermosiphonSlurryThermocoupleHeat fluxPhase-change materialThermal conductivityHeat transferComposite materialHeat pipeThermodynamicsMass flow rateMechanicsThermal

Abstract

fetched live from OpenAlex

An experimental investigation of steady, laminar, fluid flow and heat transfer in a vertical closed-loop thermosyphon operating with slurries of a microencapsulated phase-change material (MCPCM) suspended in distilled water is presented. The MCPCM particles consisted of a solid-liquid phase-change material (PCM) encapsulated in a thin polymer resin shell. Their effective diameter was in the range 0.5 to 12.5 micrometers, and had a mean value of 2.5 micrometers. The melting and freezing characteristics and the latent heat of fusion of the PCM were determined using a differential scanning calorimeter. The effective density of the MCPCM was measured, and the effective thermal conductivity of the slurries was determined using a published correlation. In the range of parameters considered, it was determined that the slurries exhibit non-Newtonian behavior. The closed-loop thermosyphon consisted of two vertical straight pipes, joined together by two vertical semi-circular 180-degree bends made of the same pipe. An essentially constant heat flux was imposed on a portion of one of the vertical pipes. The wall temperature of a portion of the other vertical pipe was maintained at a constant value. The outer surfaces of the entire thermosyphon were very well insulated. Calibrated thermocouples were used to measure the outer-wall-surface temperature at numerous points over the heated portion and the bulk temperature of the slurry at four different locations. A special procedure was formulated, benchmarked, and used to deduce the mass flow rate of the slurries in the thermosyphon. The investigation was conducted with slurries of MCPCM mass concentration 0% (pure distilled water), 7.471%, 9.997%, 12.49%, 14.95%, and 17.5%. The results are presented and discussed.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.005
Threshold uncertainty score0.421

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.023
GPT teacher head0.252
Teacher spread0.229 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2013
Admission routes2
Has abstractyes

Explore more

Same topicHeat Transfer and Boiling StudiesFrench-language works237,207