MétaCan
Menu
Back to cohort
Record W2086368512 · doi:10.1021/ac101004b

Engineered Anisotropic Microstructures for Ultrathin-Layer Chromatography

2010· article· en· W2086368512 on OpenAlexafffund
Steven R. Jim, M.T. Taschuk, Gertrud E. Morlock, Louis W. Bezuidenhout, Wolfgang Schwack, Michael J. Brett

Bibliographic record

VenueAnalytical Chemistry · 2010
Typearticle
Languageen
FieldMaterials Science
TopicOptical Coatings and Gratings
Canadian institutionsNational Institute for NanotechnologyUniversity of Alberta
FundersUniversity of Alberta
KeywordsAnisotropyMicrostructureIsotropyStationary phaseChemistryPhase (matter)MacroporeLayer (electronics)PlanarChromatographyOpticsAnalytical Chemistry (journal)Composite materialMaterials scienceCrystallographyComputer sciencePhysics

Abstract

fetched live from OpenAlex

The strong dependence of separation behavior on ultrathin-layer chromatography (UTLC) stationary phase microstructure motivates continued UTLC plate design optimization efforts. We fabricated 4.6-5.3 mum thick normal phase silica UTLC stationary phases with several types of in-plane macropore anisotropies using the glancing angle deposition (GLAD) approach to engineering nanostructured thin films. The separation behaviors of two new media, isotropic vertical posts and anisotropic bladelike films, were compared to that of anisotropic chevron media. Channel-like structures within the anisotropic media introduced preferential mobile phase flow directions that could be exploited to give separation tracks diagonal to the development direction. Extraction of chromatograms from these angled tracks required the development of a new analytical approach that involved a commercial flatbed film scanner and custom numerical image analysis software. GLAD stationary phase performance was quantified using the Dimethyl Yellow dye separated from a lipophilic dye mixture over migration distances less than approximately 10 mm. The limits of detection were 10 +/- 4 ng for the vertical posts and 11 +/- 3 ng for the bladelike media. We obtained theoretical plate heights that varied with film microstructure between 12 and 28 mum. Unoptimized separation performance was comparable to that of other planar chromatography media. Macropore anisotropies engineered by GLAD may expand the capabilities of future UTLC stationary phases.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.246
Teacher spread0.239 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".