MétaCan
Menu
Back to cohort
Record W2086712007 · doi:10.1002/mrm.22887

Atlas‐based automated positioning of outer volume suppression slices in short‐echo time 3D MR spectroscopic imaging of the human brain

2011· article· en· W2086712007 on OpenAlexaboutno aff
Kaung-Ti Yung, Weili Zheng, Chenguang Zhao, Manel Martínez‐Ramón, André van der Kouwe, Stefan Posse

Bibliographic record

VenueMagnetic Resonance in Medicine · 2011
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsnot available
FundersMinisterio de Ciencia e InnovaciónGeorgetown UniversityUniversity of WashingtonMassachusetts General HospitalU.S. Department of Energy
KeywordsComputer scienceAtlas (anatomy)VoxelMagnetic resonance imagingImaging phantomNuclear medicineNuclear magnetic resonanceArtificial intelligenceComputer visionPhysicsMedicineRadiology

Abstract

fetched live from OpenAlex

Spatial suppression of peripheral lipid-containing regions in volumetric MR spectroscopic imaging of the human brain requires placing large numbers of outer volume suppression (OVS) slices, which is time-consuming, prone to operator error and may introduce subject-dependent variability in volume coverage. We developed a novel, computationally efficient atlas-based approach for automated positioning of up to 16 OVS slices and the MR spectroscopic imaging slab. Standardized positions in Montreal Neurological Institute atlas space were established offline using a recently developed iterative optimization procedure. During the scanning session, positions in subject space were computed using affine transformation of standardized positions in Montreal Neurological Institute space. Offline analysis using magnetization prepared rapid gradient echo scans from 11 subjects demonstrated reliable OVS placement, comparable with but faster than iterative placement in subject space. This atlas-based method was further validated in 14 subjects using 3D short-echo time proton-echo-planar-spectroscopic-imaging at 3 T. Comparison of manual and automatic placement using 8 OVS slices demonstrated consistent MR spectroscopic imaging volume selection and comparable spectral quality with similar degree of lipid suppression and number of usable voxels. Automated positioning of 16 OVS slices enabled larger volume coverage, while maintaining similar spectral quality and lipid suppression. Atlas-based automatic prescription of short echo time MR spectroscopic imaging is expected to be advantageous for longitudinal and cross-sectional studies.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.003
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.312
Teacher spread0.297 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations14
Published2011
Admission routes1
Has abstractyes

Explore more

Same venueMagnetic Resonance in MedicineSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207