MétaCan
Menu
Back to cohort
Record W2087395730 · doi:10.1118/1.3560888

Minimizing dose during fluoroscopic tracking through geometric performance feedback

2011· article· en· W2087395730 on OpenAlexaff
S Siddique, Eugene Fiume, David A. Jaffray

Bibliographic record

VenueMedical Physics · 2011
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsPrincess Margaret Cancer CentreUniversity of TorontoOntario Institute for Cancer Research
FundersNational Institute on AgingNational Institutes of Health
KeywordsFluoroscopyDosimetryContext (archaeology)Tracking (education)Fiducial markerMedical imagingComputer scienceRadiosurgeryImage registrationNoise (video)NeuroradiologyComputer visionMedical physicsMedicineRadiation therapyArtificial intelligenceNuclear medicineRadiologyImage (mathematics)

Abstract

fetched live from OpenAlex

PURPOSE: There is a growing concern regarding the dose delivered during x-ray fluoroscopy guided procedures, particularly in interventional cardiology and neuroradiology, and in real-time tumor tracking radiotherapy and radiosurgery. Many of these procedures involve long treatment times, and as such, there is cause for concern regarding the dose delivered and the associated radiation related risks. An insufficient dose, however, may convey less geometric information, which may lead to inaccuracy and imprecision in intervention placement. The purpose of this study is to investigate a method for achieving the required tracking uncertainty for a given interventional procedure using minimal dose. METHODS: A simple model is used to demonstrate that a relationship exists between imaging dose and tracking uncertainty. A feedback framework is introduced that exploits this relationship to modulate the tube current (and hence the dose) in order to maintain the required uncertainty for a given interventional procedure. This framework is evaluated in the context of a fiducial tracking problem associated with image-guided radiotherapy in the lung. A particle filter algorithm is used to robustly track the fiducial as it traverses through regions of high and low quantum noise. Published motion models are incorporated in a tracking test suite to evaluate the dose-localization performance trade-offs. RESULTS: It is shown that using this framework, the entrance surface exposure can be reduced by up to 28.6% when feedback is employed to operate at a geometric tracking uncertainty of 0.3 mm. CONCLUSIONS: The analysis reveals a potentially powerful technique for dynamic optimization of fluoroscopic imaging parameters to control the applied dose by exploiting the trade-off between tracking uncertainty and x-ray exposure per frame.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.029
GPT teacher head0.278
Teacher spread0.249 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2011
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207