MétaCan
Menu
Back to cohort
Record W2088247414 · doi:10.1002/jbm.10333

Optimizing the tensile properties of polyvinyl alcohol hydrogel for the construction of a bioprosthetic heart valve stent

2002· article· en· W2088247414 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueJournal of Biomedical Materials Research · 2002
Typearticle
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsRobarts Clinical TrialsNational Research Council CanadaWestern University
Fundersnot available
KeywordsPolyvinyl alcoholMaterials scienceUltimate tensile strengthStentHeart valveDuctility (Earth science)Biomedical engineeringComposite materialSurgeryMedicineCreep

Abstract

fetched live from OpenAlex

Although bioprosthetic heart valves offer the benefits of a natural opening and closing, better hemodynamics, and avoidance of life-long anticoagulant therapy, they nevertheless tend to fail in 10-15 years from tears and calcification. Several authors, including the present ones, have identified the rigid stent as a factor contributing to these failures. The ultimate solution is an artificial heart valve that has mechanical properties that allow it to move in conformity with the aortic root during the cardiac cycle, has superior hemodynamics, is nonthrombogenic, will last more than 20 years, and mitigates the need for anticoagulants. We have identified a polymer, polyvinyl alcohol (PVA) hydrogel, that has mechanical properties similar to soft tissue. The purpose of this research is to match the tensile properties of PVA to the porcine aortic root and to fabricate a stent prototype for a bioprosthetic heart valve with the use of the PVA hydrogel. Specimens of 15% w/w PVA were prepared by processing through 1-6 cycles of freezing (-20 degrees C) at 0.2 degrees C/min freeze rate and thawing (+20 degrees C) at different thawing rates (0.2 degrees C/min and 1 degrees C/min), for different holding times (1 and 6 h) at -20 degrees C. Subsequently tensile tests and stress-relaxation tests were conducted on the specimens. The different holding times at -20 degrees C demonstrated no difference in the result. The slower thawing rate improved the tensile properties but did not produce significant changes on the stress-relaxation properties. The nonlinear stress-strain curve for the PVA after the fourth freeze-thaw cycle matched the porcine aortic root within the physiological pressure range. The stress-relaxation curve for PVA also approximated the shape of the aortic root. The complex geometry of an artificial heart valve stent was successfully injection molded. These results, in combination with other preliminary findings for biocompatibility and fatigue behavior, suggest that PVA hydrogel is a promising biomaterial for implants, catheters, and artificial skin.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.024
Threshold uncertainty score0.358

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.104
GPT teacher head0.389
Teacher spread0.285 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it