High-resolution (20 cycles/mm) digital x-ray mammography using amorphous selenium directly coupled to CCD readout devices
Bibliographic record
Abstract
A simple x-ray detector that utilizes amorphous selenium (a-Se) directly deposited on a specially-designed CCD (charge coupled device) with a 25 micrometer del (detector element) pitch is described. This simple detector has been used to test the feasibility of creating digital mammography detectors. To enable the use of electron transport CCDs with a-Se, we have developed a-Se hole blocking layers to permit the transfer of electrons to the CCD while suppressing hole leakage current in the presence of the high negative bias (~1000 V) required to make the a-Se x-ray sensitive. We report measurements of the charge transfer efficiency (CTE), dark signal, x-ray sensitivity, x-ray signal linearity, and x-ray MTF (modulation transfer function) of the simple detector. As the thickness of the a-Se hole blocking layer was increased, the MTF decreased. For a thin (1 micrometer) blocking layer the MTF at a spatial frequency of 20 cycles/mm was 0.4.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.001 |
| Bibliometrics | 0.000 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.001 |
| Open science | 0.001 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".