Biomechanical Stability of Intramedullary Nailed High Proximal Third Tibial Fractures With Cement Augmented Proximal Screws

2005· article· en· W2089092231 on OpenAlexaff
Sandra E. Roth, Hans J. Kreder, David Stephen, Cari Whyne

Bibliographic record

VenueJournal of Orthopaedic Trauma · 2005
Typearticle
Languageen
FieldMedicine
TopicBone fractures and treatments
Canadian institutionsSunnybrook Health Science Centre
Fundersnot available
KeywordsIntramedullary rodValgusCadaveric spasmMedicineInitial stabilityBiomechanicsFixation (population genetics)CadaverTibiaProximal phalanxOrthodonticsTorsion (gastropod)FemurSurgeryAnatomyImplant

Abstract

fetched live from OpenAlex

OBJECTIVE: Intramedullary nailing of nonarticular proximal tibia fractures can be affected by bone density resulting in loss of stability, fixation, and malalignment in osteopenic bone. This study was designed to quantify the biomechanical effects of augmenting proximal screws with cement in intramedullary nailing of high proximal third tibial fractures. DESIGN: In vitro biomechanical study using anatomic specimens. METHODS: Reamed nails were inserted into seven pairs of fresh-frozen cadaveric proximal tibiae and secured using two oblique and two transverse proximal screws. Paired tibiae were randomly assigned into two groups: cemented and noncemented proximal screw-holes. Bone cement was injected into the screw-holes before screw insertion in the cemented tibiae. Specimens were then tested in flexion/extension and varus/valgus to 12 Nm and in torsion to 7 Nm. Physical measurements of bone density were obtained to determine the effect of density on stability. MAIN OUTCOME MEASURES: Stability of the construct in both groups was analyzed and compared statistically using paired t tests. RESULTS: Cement augmentation of the proximal screws significantly increased mechanical stability in torsion and varus/valgus load configurations, with average decreases in rotational motion of 5.4 degrees +/- 1.6 degrees and 5.1 degrees +/- 5 degrees respectively. No change in stability was observed in flexion/extension loading. A trend toward decreased stability was seen in the uncemented construct in varus/valgus; cement augmentation of the proximal screws eliminated this effect. CONCLUSIONS: Lower bone density decreased the stability of the uncemented construct; however, cement augmentation of the proximal screws showed a trend to eliminate this effect in the varus/valgus loading configuration and should be considered when nailing proximal third tibial fractures in osteoporotic patients.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.566
Threshold uncertainty score0.867

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.273
Teacher spread0.257 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2005
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Orthopaedic TraumaSame topicBone fractures and treatmentsFrench-language works237,207