MétaCan
Menu
Back to cohort
Record W2089939378 · doi:10.1021/ac8010928

Integration of Dialysis Membranes into a Poly(dimethylsiloxane) Microfluidic Chip for Isoelectric Focusing of Proteins Using Whole-Channel Imaging Detection

2008· article· en· W2089939378 on OpenAlexaff
Junjie Ou, Tomasz Glawdel, Razim Samy, Shuwen Wang, Zhen Liu, Carolyn L. Ren, Janusz Pawliszyn

Bibliographic record

VenueAnalytical Chemistry · 2008
Typearticle
Languageen
FieldEngineering
TopicMicrofluidic and Capillary Electrophoresis Applications
Canadian institutionsUniversity of Waterloo
Fundersnot available
KeywordsChemistryIsoelectric focusingMicrofluidic chipMicrofluidicsMembraneDialysis tubingChannel (broadcasting)DialysisChromatographyChipNanotechnologyBiochemistry

Abstract

fetched live from OpenAlex

A poly(dimethylsiloxane) microfluidic chip-based cartridge is developed and reported here for protein analysis using isoelectic focusing (IEF)-whole-channel imaging detection (WCID) technology. In this design, commercial dialysis membranes are integrated to separate electrolytes and samples and to reduce undesired pressure-driven flow. Fused-silica capillaries are also incorporated in this design for sample injection and channel surface preconditioning. This structure is equivalent to that of a commercial fused-silica capillary-based cartridge for adapting to an IEF analyzer (iCE280 analyzer) to perform IEF-WCID. The successful integration of dialysis membranes into a microfluidic chip significantly improves IEF repeatability by eliminating undesired pressure-driven hydrodynamics and also makes sample injection much easier than that using the first-generation chip as reported recently. In this study, two microfluidic chips with a 100-microm-high, 100-microm-wide and a 200-microm-high, 50-microm-wide microchannel, respectively, were applied for qualitative and quantitative analysis of proteins. The mixture containing six pI markers with a pH range of 3-10 was successfully separated using IEF-WCID. The pH gradient exhibited a good linearity by plotting the pI value versus peak position, and the correlation coefficient reached 0.9994 and 0.9995 separately for the two chips. The separation of more complicated human hemoglobin control sample containing HbA, HbF, HbS, and HbC was also achieved. Additionally, for the quantitative analysis, a good linearity of IEF peak value versus myoglobin concentration in the range of 20-100 microg/mL was obtained.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.261
Threshold uncertainty score0.823

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.226
Teacher spread0.213 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations25
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueAnalytical ChemistrySame topicMicrofluidic and Capillary Electrophoresis ApplicationsFrench-language works237,207