MétaCan
Menu
Back to cohort
Record W2090069013 · doi:10.1117/12.912340

Evaluation of a fractional filter-based receive beamforming method for ultrasound color Doppler imaging

2012· article· en· W2090069013 on OpenAlexaboutno aff
Hana Yang, Jeeun Kang, Jin Ho Chang, Yangmo Yoo

Bibliographic record

VenueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2012
Typearticle
Languageen
FieldMedicine
TopicUltrasound Imaging and Elastography
Canadian institutionsnot available
Fundersnot available
KeywordsBeamformingImaging phantomComputer scienceFilter (signal processing)Sampling (signal processing)Doppler effectRadio frequencyAcousticsAlgorithmPhysicsOpticsComputer visionTelecommunications

Abstract

fetched live from OpenAlex

In medical ultrasound imaging, dynamic receive beamforming has been used for improving signal-to-noise ratio (SNR) and spatial resolution. For low-cost portable ultrasound imaging systems, a fractional filter-based receive beamforming (FFRB) method was previously proposed to reduce the hardware complexity compared to conventional interpolation filter-based receive beamforming methods (IFRB). While this new beamforming method substantially reduces the hardware complexity, it yields the nonlinear phase response for high frequencies due to the limited length of fractional filter coefficients, leading to the bias on flow estimation in ultrasound color Doppler imaging. In this paper, to evaluate the FFRB method for ultrasound color Doppler imaging, the Field II simulation and string phantom experiments were conducted. In Field II simulation, the radio-frequency (RF) data were generated by assuming a 7.5-MHz linear array probe with the transmit frequency of 6 MHz, the ensemble size of 8, and the sampling frequencies of 20 MHz. In string phantom experiments, the RF channel data were obtained with a commercial SonixTouch ultrasound scanner equipped with a research package (Ultrasonix Corp., Vancouver, BC, Canada) and a 5-MHz linear array connected to a SonixDAQ parallel system. The ensemble size and the sampling frequency were set to 10 and 20 MHz, respectively. For the Field II simulation and string phantom experiments, only 1.2% and 2.3 % in color Doppler estimation error ratio was observed with mean and standard deviation along the lateral direction. This result indicates that the proposed FFRB method could be utilized for a low-cost ultrasound color Doppler imaging system with lowered hardware complexity and minimized phase errors.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.004
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.291
Teacher spread0.270 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIESame topicUltrasound Imaging and ElastographyFrench-language works237,207