Current Practice in the Intramedullary Nailing of Tibial Shaft Fractures: An International Survey
Bibliographic record
Abstract
BACKGROUND: Tibial fractures are the most common of all long bone fractures. Although many tibial fractures may be managed conservatively, a certain subset, including unstable fractures and open fractures, require operative stabilization. Intramedullary nails have become the popular choice of implant in the treatment of tibial shaft fractures. The variability in outcomes with tibial shaft fractures may reflect technical aspects of the surgical procedure and perioperative care regimens among surgeons. Identifying the distribution of surgeons' preferences in nailing technique, and the rationale for their choices, will aid in focusing educational activities for the orthopedic community and planning future clinical trials. Our objectives were to clarify surgeons' opinions regarding technical aspects of surgery and perioperative care after intramedullary nailing of closed and open tibial shaft fractures, and to identify predictors of surgeons' preferences in technique and perioperative care. METHODS: This study was a cross-sectional survey using focus groups, key informants, and sampling to redundancy strategies to develop a survey to examine surgeons' preferences in the treatment of tibial shaft fractures. The survey was pilot tested for clarity and content validity. We mailed this survey in July 2000 to 577 orthopedic surgeons who have an interest in trauma care. These were members of the Orthopaedic Trauma Association, American Academy of Orthopaedic Surgeons, or European AO International affiliated trauma centers. We used several strategies to improve response rates including personalized cover letters, stamped return envelopes, follow-up telephone calls, and repeat mailing of questionnaires. Main outcome measures included technical issues such as reduction, exposure, intramedullary reaming, and interlocking screws; and factors associated with surgeons' preferences such as age, fellowship, academic practice, and geographic location. RESULTS: Four hundred forty-four surgeons (77%) responded. Sixty percent of respondents had an academic practice, 84% supervised residents, and 65.1% had fellowship training in trauma. Approximately half (51.5%) of surgeons used a tourniquet. The odds that a surgeon in Asia or Africa used tourniquets was 10 times that of a North American surgeon (p = 0.004 and p = 0.002, respectively). Patellar tendon retraction and an inferior-based entry portal was the popular choice among surgeons (70.1% and 70.8%, respectively). Surgeons from Australia (odds ratio [OR] = 50, p < 0.001), South America (OR = 9.0, p < 0.001), Europe (OR = 3.7, p = 0.001), and Asia (OR = 3.8, p = 0.006) were significantly more likely to use a patellar splitting approach compared with North American surgeons. In the perioperative care of open tibial shaft fractures, there was consensus in the use of intravenous antibiotics and wound irrigation (96.5% and 95.6%, respectively). However, we found considerable variability in surgeons' preference in wound irrigation pressures (high, 38.7%; low, 45.4%). Surgeons in South America were 10 times more likely to use low-pressure irrigation than North American surgeons (p = 0.0005). In grade IIIB open tibial shaft fractures, 94% of surgeons believed wound closure should be obtained within the first 7 days after the injury. A surgeon's geographic location was a significant predictor of the timing of soft tissue coverage (p = 0.001). CONCLUSION: Consensus in the use of irrigation and intravenous antibiotics in open fractures was achieved among surgeons. However, there remains considerable variability in the surgical technique of intramedullary nailing, the duration of antibiotic use, and the timing of wound closure in open tibial fracture care. Continued education and large multicenter trials are needed to establish best practice in the operative treatment of tibial shaft fracture.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.002 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.001 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".