MétaCan
Menu
Back to cohort
Record W2090758602 · doi:10.1117/12.2081537

Vibration effect on cross-flow and co-flow focusing mechanism for droplet generation

2015· article· en· W2090758602 on OpenAlexafffund
Alinaghi Salari, Colin Dalton

Bibliographic record

VenueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2015
Typearticle
Languageen
FieldEngineering
TopicInnovative Microfluidic and Catalytic Techniques Innovation
Canadian institutionsUniversity of Calgary
FundersNatural Sciences and Engineering Research Council of CanadaCMC Microsystems
KeywordsMicrochannelBreakupMechanicsVibrationFlow focusingFlow (mathematics)Capillary actionFinite element methodMaterials sciencePhysicsVolumetric flow rateAcousticsThermodynamics

Abstract

fetched live from OpenAlex

Microbubbles are widely used in many industries such as water treatment, drug coating, and ultrasonic contrast agents. Cross-flow focusing and co-flow focusing are considered basic mechanisms used for microbubble generation. Typically, to achieve micron-sized droplets requires structure dimensions in the same order of magnitude of the desired droplet sizes. In this paper we report a method of applying an external vibration to a cross-flow and co-flow focusing structure, which allows for smaller droplets to be generated. The junction dimension was 700×400 μm, and the channel width was 800 μm. The two assumed fluids are selected in a way that the Capillary number is high (Ca>10) to make use of necking effect occurred in the downstream. Linear vibration was exerted on the microchannel structure in the direction of central flow. A 2D structure was simulated using finite element software, and the numerical approach was then verified by comparing the experimental data of a typical cross-flow focusing structure taken from our previous study with the corresponding simulation assuming the same parameters. The results show that although the droplet generation regime depends on flow ratio (Qa/Qw) and vibration parameter (ampl×freq), Capillary number also has a significant effect on the regime. Briefly, applying a low-cost linear vibration to the conventional flow focusing structures can be used as an accurate controlling technique for increasing the chance of droplet generation. In fact, vibration motion can change the flow regime and breakup mechanism. It can also change the breakup point at which the droplets are formed.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.253
Teacher spread0.236 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2015
Admission routes2
Has abstractyes

Explore more

Same venueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIESame topicInnovative Microfluidic and Catalytic Techniques InnovationFrench-language works237,207