MétaCan
Menu
Back to cohort

Quantity and Conformation of Lysozyme Deposited on Conventional and Silicone Hydrogel Contact Lens Materials Using an In Vitro Model

2007· article· en· W2091110762 on OpenAlex
Maciej Suwala, Mary-Ann Glasier, Lakshman N. Subbaraman, Lyndon Jones

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueEye & Contact Lens Science & Clinical Practice · 2007
Typearticle
Languageen
FieldMedicine
TopicOcular Surface and Contact Lens
Canadian institutionsUniversity of Waterloo
Fundersnot available
KeywordsSilicone hydrogelLysozymeContact lensLens (geology)ChemistryChromatographyOphthalmologyOpticsBiochemistryMedicine

Abstract

fetched live from OpenAlex

PURPOSE: To determine the activity of hen egg lysozyme (HEL) deposited on conventional and silicone hydrogel contact lens materials by using an in vitro model. METHODS: ACUVUE 2 (etafilcon A), PureVision (balafilcon A), ACUVUE Advance (galyfilcon A), Focus NIGHT & DAY (lotrafilcon A), O2 Optix (lotrafilcon B), Proclear (omafilcon A), and ACUVUE OASYS (senofilcon A) contact lenses were deposited in vitro in a phosphate-buffered solution (PBS) containing 2 mg/mL HEL. Lenses were briefly rinsed in PBS to remove unbound material and extracted in a mixture of acetonitrile and trifluoroacetic acid. After lyophilization, extracts were examined for lysozyme activity by micrococcal assay and total protein by Western blot. RESULTS: In terms of total protein accumulation, ACUVUE 2 showed the most, with 1,800 microg per lens. Proclear was next, with 68 microg per lens, and Focus NIGHT & DAY showed the least, with 2 microg per lens. ACUVUE Advance, ACUVUE OASYS, and O2 Optix accumulated similar amounts of lysozyme, at approximately 6 microg per lens. Lysozyme deposited on ACUVUE 2 showed the greatest activity (91% +/- 5%), and this result was statistically different from all other lens types (P<0.001). Lysozyme deposited on Focus NIGHT & DAY (24% +/- 5%) and O2 Optix (23% +/- 11%) showed the lowest activity. Lysozyme deposits on other lens materials showed intermediate activity (ACUVUE Advance, 60% +/- 15%; ACUVUE OASYS, 51% +/- 9%; PureVision, 58% +/- 8%; and Proclear, 38% +/- 3%). CONCLUSIONS: Silicone hydrogel lenses acquire less lysozyme deposit than conventional group II (Proclear) or group IV (ACUVUE 2) lenses do, and the levels of activity of the lysozyme are highly variable between materials.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.007
metaresearch head score (Gemma)0.003
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.555
Threshold uncertainty score0.957

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0070.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.003
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.086
GPT teacher head0.412
Teacher spread0.326 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it