MétaCan
Menu
Back to cohort
Record W2091379182 · doi:10.1117/12.818802

Compact narrow linewidth semiconductor laser module

2009· article· en· W2091379182 on OpenAlex
M. Poulin, S. Ayotte, C. Latrasse, Y. Painchaud, Jean-François Cliche, A. Babin, M. Aubé, M.-J. Picard, F. Costin, M. Têtu, Ghislain Lafrance

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2009
Typearticle
Languageen
FieldEngineering
TopicSemiconductor Lasers and Optical Devices
Canadian institutionsTeraXion (Canada)
Fundersnot available
KeywordsLaser linewidthLaserSemiconductor laser theoryOptoelectronicsDiscriminatorPhase noiseOpticsPhotonicsInterferometryDistributed feedback laserMaterials scienceRealization (probability)Injection seederTunable laserNoise (video)Computer sciencePhysics

Abstract

fetched live from OpenAlex

Frequency noise reduction of semiconductor lasers using electrical feedback from an optical frequency discriminator is an efficient and simple approach to realize narrow linewidth lasers. These lasers are of great interest for applications such as LIDAR, RF photonics and interferometric sensing. In this paper, we review the technological choices made by TeraXion for the realization of its Narrow Linewidth Laser modules. The method enables to decrease the linewidth of DFB lasers from several hundreds of kHz to a few kHz. We present the work in progress to integrate such system into a miniature package and to incorporate advanced functionalities such as multi-laser phase locking.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.171
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.226
Teacher spread0.213 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it