MétaCan
Menu
Back to cohort
Record W2091444505 · doi:10.1002/mrm.10831

Functional magnetic resonance imaging of the human brain based on signal enhancement by extravascular protons (SEEP fMRI)

2003· article· en· W2091444505 on OpenAlexaff
Patrick W. Stroman, Bogusław Tomanek, Vanessa Krause, Uta Frankenstein, Krisztina L. Malisza

Bibliographic record

VenueMagnetic Resonance in Medicine · 2003
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsUniversity of CalgaryNational Research Council Institute for Biodiagnostics
Fundersnot available
KeywordsFunctional magnetic resonance imagingNuclear magnetic resonanceEcho timeContrast (vision)Magnetic resonance imagingHuman brainSIGNAL (programming language)Communication noiseSensitivity (control systems)NeuroimagingPhysicsComputer scienceNeuroscienceArtificial intelligenceMedicinePsychologyRadiology

Abstract

fetched live from OpenAlex

Functional magnetic resonance imaging (fMRI) studies of the human brain were carried out at 3 Tesla to investigate an fMRI contrast mechanism that does not arise from the blood oxygen-level dependent (BOLD) effect. This contrast mechanism, signal enhancement by extravascular protons (SEEP), involves only proton-density changes and was recently demonstrated to contribute to fMRI signal changes in the spinal cord. In the present study it is hypothesized that SEEP fMRI can be used to identify areas of neuronal activity in the brain with as much sensitivity and precision as can be achieved with BOLD fMRI. A detailed analysis of the areas of activity, signal intensity time courses, and the contrast-to-noise ratio (CNR), is also presented and compared with the BOLD fMRI results. Experiments were carried out with subjects performing a simple finger-touching task, or observing an alternating checkerboard pattern. Data were acquired using a conventional BOLD fMRI method (gradient-echo (GE) EPI, TE = 30 ms), a conventional method with reduced BOLD sensitivity (GE-EPI, TE = 12 ms), and SEEP fMRI (spin-echo (SE) EPI, TE = 22 ms). The results of this study demonstrate that SEEP fMRI may provide better spatial localization of areas of neuronal activity, and a higher CNR than conventional BOLD fMRI, and has the added benefit of lower sensitivity to field inhomogeneities.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.287
Teacher spread0.273 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations60
Published2003
Admission routes1
Has abstractyes

Explore more

Same venueMagnetic Resonance in MedicineSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207