MétaCan
Menu
Back to cohort

Influence of Implant Connection Type on the Biomechanical Environment of Immediately Placed Implants – CT‐Based Nonlinear, Three‐Dimensional Finite Element Analysis

2009· article· en· W2091497988 on OpenAlexvenueno aff
Roberto Sales e Pessoa, Luiza Muraru, Élcio Marcantônio, Luı́s Geraldo Vaz, Jos Vander Sloten, Joke Duyck, Siegfried Jaecques

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2009
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
FundersUniversidade Estadual Paulista
KeywordsAbutmentOsseointegrationImplantMaterials scienceDisplacement (psychology)von Mises yield criterionStress (linguistics)Finite element methodDental AbutmentsDentistryOrthodonticsStructural engineeringBiomedical engineeringEngineeringMedicineSurgery

Abstract

fetched live from OpenAlex

PURPOSE: The purpose of the present study was to evaluate the biomechanical environment of immediately placed implants, before and after osseointegration, by comparing three different implant-abutment connection types. MATERIALS AND METHODS: A computer tomography-based finite element model of an upper central incisor extraction socket was constructed containing implants with either external hex, internal hex, or Morse-taper connection. Frictional contact elements were used in the bone, implant, abutment, and abutment screw interfaces in the immediately placed simulations. In osseointegrated simulations, the repair of bone alveolar defect and a glued bone-to-implant interface were assumed. By analysis of variance, the influence was assessed of connection type, clinical situation, and loading magnitude on the peak equivalent strain in the bone, peak von Mises stress in the abutment screw, bone-to-implant relative displacement, and abutment gap. RESULTS: The loading magnitudes had a significant contribution, regardless of the assessed variable. However, the critical clinical situation of an immediately placed implant itself was the main factor affecting the peak equivalent strain in the bone and bone-to-implant displacement. The largest influence of the connection type in this protocol was seen on the peak equivalent stress in the abutment screw. On the other hand, a higher influence of the various connection types on bone stress/strain could be noted in osseointegrated simulations. CONCLUSIONS: The implant-abutment connection design did not significantly influence the biomechanical environment of immediately placed implants. Avoiding implant overloading and ensuring a sufficient initial intraosseous stability are the most relevant parameters for the promotion of a safe biomechanical environment in this protocol.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.540
Threshold uncertainty score0.789

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.095
GPT teacher head0.418
Teacher spread0.323 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations145
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related ResearchSame topicDental Implant Techniques and OutcomesFrench-language works237,207