Abstract

fetched live from OpenAlex

BACKGROUND: Metal-on-metal bearings in surface arthroplasty are associated with prolonged periods of elevated ion circulation. However, there exists some controversy regarding the effect of different surgical variables on the concentration of metal ions in whole blood of patients after hip resurfacing. QUESTIONS/PURPOSES: We sought to confirm which clinical and radiographic parameters are associated with elevated levels of cobalt, chromium, and molybdenum after unilateral metal-on-metal surface arthroplasty. METHODS: We retrospectively reviewed 91 patients with a minimum followup of 24 months (mean, 37 months; range, 24-55 months). The clinical variables consisted of age, gender, preoperative severity of osteoarthritis, component size, and functional outcome measures using the Harris hip score and UCLA activity score. The radiographic parameters included acetabular inclination and version as well as femoral component alignment from both the anteroposterior and lateral radiographs. RESULTS: A smaller femoral head diameter was associated with larger levels of cobalt and chromium. We observed a negative correlation between ion levels and the Harris hip score or UCLA score. A larger acetabular inclination showed a direct relationship with the concentration of metal ions. Severity of preoperative osteoarthritis, acetabular version, femoral stem-shaft and valgus angle, and anterior orientation of the femoral component had no effect on the circulating metal ion levels. CONCLUSIONS: The data suggest a smaller implant diameter, larger cup inclination, and lower postoperative functional scores are associated with increased cobalt and chromium levels after metal-on-metal hip resurfacing.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.072
GPT teacher head0.414
Teacher spread0.342 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations50
Published2010
Admission routes1
Has abstractyes

Explore more

Same venueClinical Orthopaedics and Related ResearchSame topicOrthopaedic implants and arthroplastyFrench-language works237,207